Showing 1–24 of 54 results

FumiSense Pro MBr- Lo

FumiSense Pro MBr- Lo

FumiSense Pro-Lo is a handheld Methyl Bromide monitor for monitoring Methyl Bromide levels outside the fumigated stack/ silo/ ship to check for leaks. Equipped with an inbuilt air sampling pump and with the ability to measure MBr up to 200 ppm, it is the perfect tool for this application. The backlit OLED display enables the user to read the instrument display even in the dark. With user settable datalogging features, the device logs gas concentration values with date, time and location.

FumiSense Pro PH3 – Lo

FumiSense Pro PH3 – Lo

FumiSense Pro-Lo is a handheld Phosphine monitor for monitoring phosphine levels outside the fumigated stack/ silo/ ship to check for leaks and to ensure the level of PH3 is less than the TLV. Equipped with an inbuilt air sampling pump and with the ability to measure PH3 up to 20 ppm, it is the perfect tool for this application. The backlit OLED display enables the user to read the instrument display even in the dark. With user settable datalogging features, the device logs gas concentration values with date, time and location.

Membrane Based Sample Handling System

Membrane Based Sample Handling System

Sample Extraction and Conditioning System or Membrane based Sample Conditioning System 

“Membrane based sample conditioning system is for dry sample extraction. This is needed where highly soluble and corrosive acidic gases are present in the sample to be extracted. It reduces the dust load and moisture content in the sample to transport it to CEMS without a heated sampling line. This reduces the running cost of the overall system. The system is specially designed for extracting highly corrosive gases like HBr, F2, HF, HCl and Cl2 from the stack. The system can be directly mounted on the stack with the flange connections and is used where the stack temperatures are <100°C and where very low dewpoints are necessary. The power required to run the system and the necessary communication is established from the CEMS through a cable running between them. “ 

Uniphos Tubes

Detector Tube Technology 

The Uniphos brand of detector tubes are used with the precision ASP-40 piston hand pump. The air sample is drawn through the narrow tube containing a specific gas sensing chemical causing a color change.  The length of color stain gives the concentration which is read directly from the measurement scale printed on the tube. The piston style pump and tube configuration often have the measurement based on a single pump stroke.  

Uniphos detector tubes provide a simple measurement of chemicals in gas samples. Since the tubes are pre-calibrated, no calibration is necessary and hence are absolutely free of maintenance.  

More than 250 different Uniphos Gas Detection Tubes are available for over 150 different chemicals and concentration ranges  

Uniphos Online COD Analyzer (Potentiometric Method)

Uniphos Online COD Analyzer
(Potentiometric Method)

Chemical Oxygen demand is defined as the amount of oxygen required for the oxidation of all the organic compounds present in a water sample.  

The Uniphos online COD analyzer is a programmable, fully automatic analyzer which measures COD of waste / effluent water samples using a direct method of analysis. This direct method involves oxidation of sample by potassium dichromate and measurement by potentiometric titration. No human intervention is required during the measurement, as the analyzer is completely automated.
The inbuilt diagnostics feature gives an alarm if there are any faulty components or if the reagent level goes below the minimum level. Equipped with a next generation touchscreen HMI for display and programming, the analyzer provides a variety of data communication options such as RS-485 MODBUS and industry standard 4-20 mA analog output 

Phosphine Detector Strips

Phosphine Detector Strips

Phosphine detector strips alert workers of the presence of PH3 in dangerous levels.  The strips change colour from their original yellow to pink when exposed to PH3 gas. The time it takes to change colour can be related to the PH3 gas concentration in the environment.  They can be used to check the fumigated area for the presence of PH3 after aeration is complete and to confirm that the area is safe for re-entry. These strips can also be given to workers as badges when they are working in/near fumigated structures.  

FumiSpec-Hi

FumiSpec-Hi

Sulfuryl Fluoride is a colorless and odorless gas. It is used as a fumigant in structural and commodity fumigations to control dry wood termites, wood-infesting beetles, and other insects. Like any other fumigant, Inhalation of Sulfuryl Fluoride is very dangerous to human beings and can lead to serious illness or death.  Hence, it is very important to monitor the gas concentrations inside the fumigated area space during the entire fumigation period.  

The Uniphos FumiSpec-Hi is a fully automatic NDIR based Sulfuryl Fluoride analyzer. Housed in a rugged Pelican storm case it continuously monitors gas concentrations in the fumigated space. It can be used as a single port analyzer or as a multi-port analyzer when connected to an Expansion Pack. It is equipped with an inbuilt sampling pump and comes with User-Settable sampling time for each port. The USB interface present in the FumiSpec-Hi enables data logging and the data storage capacity depends on the memory of the flash drive connected to it. 

NDIR Stack Gas Analyzer

NDIR Stack Gas Analyzer

All diatomic and polyatomic molecules have one or several vibrational modes which can absorb radiation and give rise to a unique absorption spectrum in the infrared region with several absorption lines. Taking any one of the IR absorption lines of the target gas as its finger print, an instrument can be built for measurement of target gas concentration. Infrared technique is endowed with very high specificity when a right choice of the vibrational frequency of the target molecule is madeThis technique is cost effective and reliable for measurement of gas concentration in parts per million range. 

The Uniphos NDIR Stack Gas Analyzer are endowed with specificity and have adequate sensitivity for the detection of gases like SO2, NOx, CO, CO2 and CH4 in industrial stacks. The in-built powerful pump enables the analyzer to draw the sample from stack. Analyzer is equipped with the latest embedded and IOT technologies which enables the user to perform Remote calibration. This PLC based analyser incorporates all desired features which makes it user-friendly and fail safe.

Uniphos Pro

Uniphos Pro

The Uniphos Pro is a portable gas monitor that idesigned with durability and reliability in mind. It comes with an OLED display which clearly shows the gas concentration, battery level, and other information needed to operate and set up the instrument for use. The backlit OLED display enables the user to read the concentration levels even in dark. With user-settable data logging features the device can logs gas concentration values with date and time.

The Uniphos pro can be used to measure various types of Toxic, flammable, and hazardous gases. With loud 85 dB audible alarms, the user is instantly alerted once gas levels breach the set alarm limits.  

Uniphos Online Total Cyanide Analyzer

Uniphos Online Total Cyanide Analyzer

Total Cyanide in effluent water refers to the sum of all cyanide-containing compounds, including free/ weak acid as well as dissociable and strong metal cyanide complexes.  

The Uniphos online Cyanide analyzer is a reliable, fully automatic analyzer designed to measure the total cyanide of waste / effluent water samples by an ASTM 7511-09 method. The ASTM 7511-09 method involves acid digestion with UV irradiation and determination of total cyanide by amperometric method. The amperometric technique used is demonstrated to be free of analytical interferences and eliminates the use of hazardous reagents. No human intervention is required during the measurement as the analyzer is completely automated.
The inbuilt diagnostics feature gives an alarm if there are any faulty components or if the reagent level goes below the minimum level. Equipped with a next generation touchscreen HMI for display and programming, the analyzer provides a variety of data communication options such as RS-485 MODBUS and industry standard 4-20 mA analog output 

Single Port FumiTrack

Single Port FumiTrack

The Uniphos Single Port FumiTrack delivers unmatched performance for the detection and continuous monitoring of Hi and / or Lo concentration Phosphine during Fumigation. The unit draws gas samples at pre-determined intervals from inside the fumigation chamber / silo / container with a powerful inbuilt air sampling pump capable of drawing from upto 100m of tubing. Equipped with the latest embedded and IoT technologies, the inbuilt GSM modem pushes data to the cloud and enables the user to remotely monitor gas concentrations of the fumigant and ensure that they are at the right levels at all times during the entire fumigation process.  

FumiTrack Multiport with Expansion Module

FumiTrack Multiport with Expansion Module

Uniphos Multiport FumiTrack is a portable, programmable, fully automatic multi-port gas monitor for the periodic monitoring of Methyl Bromide during Fumigation. Housed in a tough Pelican Storm Case, it provides superior protection in tough environments. The multi-port FumiTrack is capable of periodic measurement from up to 4 ports at user-settable intervals. With the addition of an 8-port expansion pack, monitoring can be expanded from up to 12 ports.  Equipped with the latest embedded and IoT technologies, the inbuilt GSM modem pushes data to the cloud and enables the user to remotely monitor gas concentration levels, with information like Cycle No., Date, Time, Site & Location. Once programmed, the FumiTrack will work automatically, without any human intervention, for the entire fumigation period, enabling the user to remotely monitor the fumigation from anywhere in the world.

Peltier Based Sample Handling System

Peltier Based Sample Handling System

The Uniphos Peltier Cooled Probe is an advanced sample conditioning system to draw a gas sample from an emissions stack being monitored. Sample extraction and conditioning is an important part of all Continuous Emission Monitoring Systems (CEMS) and includes extracting the sample from the stack and maintaining the dew point of the sample at such a level that there is no condensation at any point until the concentration of the sample is measured. This ensures proper transport and measurement of sample concentrations.  

The Peltier Cooled Probe is a unique product which is based on an advanced hot and dry extractive technique where the sample is extracted and conditioned on the stack and transported to the analyzer using a non-heated sampling tube at ambient temperature. It consists of a stack mountable system which includes a heated probe, a short, heated sampling line and a Peltier cooled sample conditioning module, all integrated in a single enclosure. Using a Peltier Cooled Probe reduces the length of the heated sampling line to less than half a meter, bringing down the operating cost many times. 

Uniphos Ansidine Value Meter

Uniphos Ansidine Value Meter

The Uniphos p-Anisidine value meter is a light weight, low cost, microprocessor-based instrument tailor made for the measurement of p-anisidine value of edible oil. It operates on the principle of optical absorption to determine the anisidine value. The chemical analysis method of p-Anisidine Value determines the amount of aldehydes (principally 2-alkenals and 2,4-dienals) in animal and vegetable oils and fats. This easy-to-use battery-operated instrument features an intuitive user interface and has in-built data logging facility as standard. 

Uniphos TSS probe with Controller

Uniphos TSS probe with Controller

The Uniphos TSS probe utilizes optical spectroscopic technique to determine the presence of suspended solids in Industrial wastewater, surface water, etc.  Utilizing an IR light source and IR detector to determine the TSS, as well as a solenoid valve for auto purging/ cleaning the sensor, the instrument provides an accurate and affordable solution for TSS monitoring in wastewater.

Equipped with a next generation touchscreen HMI controller for display and programming the unit, the probe provides a variety of data communication options such as RS-485 MODBUS and industry standard 4-20 mA analog output. 

Uniphos ASP-40 Air Sampling Pump and Accessories

The Uniphos ASP-40 pump is a light weight and rugged piston and barrel type of air sampling pump that creates a vacuum in the pump barrel causing it to draw an accurate volume of sample air through the connected gas detector tube. The integrated end-of-stroke indicator changes colour to indicate the completion of sampling. The Uniphos ASP-40 pump is easy to operate and is designed for use with the entire Uniphos gas detector tube range.

Uniphos Envirotrack

Uniphos Envirotrack

The Uniphos Envirotrack is microprocessor based portable instrument custom made to measure the pollutants in the Ambient Air. It comes with an Air sampler where the sample air is scrubbed in a solution specific to the pollutant. The pollutant gas dissolves in the gas specific chemical and is further processed to produce a colored dye. The instrument measures the absorbance of light passed through this colored dye and relates it to the concentration of pollutants in ppb levels.  
With datalogging included as standard and the presence of a USB interface, the user can easily transfer the stored data along with time and date to a computer. 

FumiTrack – Single Port

FumiTrack – Single Port

TheUniphosSingle PortFumiTrackdelivers unmatched performancefor the detection and continuous monitoring of Methyl Bromide during Fumigation.The unit draws gas samples at pre-determined intervals from inside the fumigation chamber / silo / container with a powerful inbuilt air sampling pump capable of drawing fromupto100m of tubing. Equipped with the latest embedded and IoT technologies, the inbuilt GSM modem pushes data to the cloud and enables the usertoremotelymonitor gas concentrations of the fumigantand ensure that they are at the right levels at all times during the entire fumigation process. 

Remote Calibration

Remote Calibration

Remote calibration is the process of remotely triggering either zero or span calibration for a gas analyzer through a web portal. The remote calibration feature in the Uniphos CEMS not only enables access to the analyzer remotely but also assists in performing various activities like zeroing, calibration and validation of the analyzer remotely.

Uniphos FFA Meter

Uniphos FFA Meter

Uniphos Free Fatty acids is an ideal instrument for the determination of acid value of edible Oil samples.  The fatty acids in the oil get detached from the triglycerides during processing or improper storage. These free fatty acids contribute to oil rancidity and cause deterioration in flavour of the oil. The sample oil is first treated with a variety of reagents to create a colored dye. The instrument measures the absorbance of the light passed through this colored dye and relates it to the free fatty acids as % of Oleic acid. With datalogging included as standard and the USB interface present in the instrument allows the user to easily transfer the stored data along with time and date to a computer. 

UV-VIS COD-TSS Probe with Controller

UV-VIS COD-TSS Probe with Controller

Operating on the principle of absorption spectroscopic technique to measure COD, BOD & TSS in Industrial wastewater, surface water, etc., the probe is equipped with a solenoid valve which is capable of auto purging/ cleaning the sensor. The Light source and UV detector present in the instrument provide an accurate measurement of COD, BOD, & TSS in wastewater.  
 
Equipped with a next generation touchscreen HMI controller for display and programming the unit, the probe provides a variety of data communication options such as RS-485 MODBUS and industry standard 4-20 mA analog output. The analyser is also programmed to display BOD value of known matrix 

Boreal Gasfinder3-MC

Boreal Gasfinder3-MC

The Gasfinder3-MC is an all-in-one field mountable multi-channel analyzer which can detect two different target gases for fast leak detection and ambient monitoring.

For more information click here.

Hospital Oxygen Monitor

Hospital Oxygen Monitor

The COVID-19 pandemic has affected nearly every country in the world. The rise in infections has overloaded hospitals, resulting in the use of huge quantities of Oxygen in COVID wards and especially ICU’s. The recent spate of fire related accidents in hospitals across India can mostly be traced to the leakage of Oxygen. Most people, including hospital administrators may not be aware that Oxygen, in higher concentrations can present a major fire hazard. Hence, it is imperative that oxygen leak detectors are installed in ICU’s and wards.

Uniphos understands these needs and is committed to working with hospitals to provide a safe environment to patients and staff. This easy to install, made in India product can be a life saver in these trying time. The oxygen monitor activates an alarm when it detects any oxygen leakage.

Simple Sampling Probe

Simple Sampling Probe

The Uniphos Simple Sampling probe is tailor made for situations where temperature of the stack is not high, and condensation does not happen while extracting the sample from the stack. The dust filter present in the probe ensures that no dust is passed through the line.  User-Settable purging facility enables automatic purging of the probe at pre-defined time intervals.