Phosphine detector strips alert workers of the presence of PH3 in dangerous levels. The strips change colour from their original yellow to pink when exposed to PH3 gas. The time it takes to change colour can be related to the PH3 gas concentration in the environment. They can be used to check the fumigated area for the presence of PH3 after aeration is complete and to confirm that the area is safe for re-entry. These strips can also be given to workers as badges when they are working in/near fumigated structures.
Portable COD Analyzer with Digester
Portable COD Analyzer with Digester
Chemical Oxygen demand is defined as the amount of oxygen required for the oxidation of all the organic compounds present in the water sample.
The portable, microprocessor based Uniphos COD analyzer operates on the non-dispersive absorption principle to measure COD of waste / effluent water samples. This easy to use battery operated analyzer features an easy to use intuitive interface and has in-built data logging facility as standard. The stored data can either be exported to a computer or printed as a report to a RS-232 printer.
A COD Digester is also provided with the COD analyzer for digestion of the water sample mixed with reagents. It is a robust instrument capable of accommodating 25 vials at a time. A PID controller in the digester ensures that all the samples are heated precisely to 150oC.
Remote Calibration
Remote Calibration
Remote calibration is the process of remotely triggering either zero or span calibration for a gas analyzer through a web portal. The remote calibration feature in the Uniphos CEMS not only enables access to the analyzer remotely but also assists in performing various activities like zeroing, calibration and validation of the analyzer remotely.
Simple Sampling Probe
Simple Sampling Probe
The Uniphos Simple Sampling probe is tailor made for situations where temperature of the stack is not high, and condensation does not happen while extracting the sample from the stack. The dust filter present in the probe ensures that no dust is passed through the line. User-Settable purging facility enables automatic purging of the probe at pre-defined time intervals.
Single Port FumiTrack
Single Port FumiTrack
The Uniphos Single Port FumiTrack delivers unmatched performance for the detection and continuous monitoring of Hi and / or Lo concentration Phosphine during Fumigation. The unit draws gas samples at pre-determined intervals from inside the fumigation chamber / silo / container with a powerful inbuilt air sampling pump capable of drawing from upto 100m of tubing. Equipped with the latest embedded and IoT technologies, the inbuilt GSM modem pushes data to the cloud and enables the user to remotely monitor gas concentrations of the fumigant and ensure that they are at the right levels at all times during the entire fumigation process.
Stack/Duct Probe
TDLAS Based Gas Analyser
TDLAS Based Gas Analyser
The TDLAS (Tunable Diode Laser Absorption Spectroscopy) technique in combination with WMS (wavelength modulation spectroscopy) is highly sensitive and specific method for detection of gases and is an excellent technique for concentration measurement of gaseous species in scientific as well as industrial applications. Uniphos TDLAS based gas analyzer are exceptionally reliable for trace level detection of atmospheric pollutants like HF, HCl, NH3 etc. Our TDLAS based analyser provides an accurate and real time measurements of these atmospheric pollutants from ppm levels to percentage levels.
TPF Probe
TPF Probe
The emission of pollutants such as CO, CO2, NO, NO2, total NOx, SO2 etc. from stacks are often measured and reported for regulatory compliance purposes on a mass flow rate basis. Mass flow rates are typically calculated and reported in units of lbs or kg per hour and tons per year for these pollutants. The pollutant mass flow rate is a function of the pollutant concentration of the stack gas, the stack size & shape, and the stack gas velocity.
The Uniphos Integrated Temperature, Pressure and Flow Probe is meant for continuous and real time measurement of Temperature, Pressure and velocity of gases in industrial stacks. All the three sensors are integrated on a single flange and can easily be mounted on the stack without any hassle.
Uniphos 500 H16 Multi Channel controller with HMI
Uniphos 500 H16 Multi Channel controller with HMI
The Uniphos 500 H16 is an adaptable, compact MODBUS based controller which can connect up to 8 to 16 numbers of KwikSense Gas Transmitters. It comes in 2 variants – 8 channel and 16 channels. Being a Modbus Scanner, it receives data in MODBUS RTU format from the digital gas transmitters and displays the required output on its screen. Each channel in the controller is user settable for alarms, tags etc. The Uniphos 500 H16 has 3 common potential-free relay contacts to control alarms or any other equipment. The on-board data logging allows easy access to historical data via a USB interface.
Uniphos 500 HA12 Multichannel Controller with HMI
Uniphos 500 HA12 Multichannel Controller with HMI
The Uniphos 500 HA12 is a robust Multi Channel controller which can connect a maximum of 12 nos. of KwikSense Gas Transmitters. Being an analog controller, it accepts 4-20 mA input from the transmitters and displays the required output on its 7’’ TFT touchscreen. Each channel in the controller is user settable for range, resolution, alarms, tags etc. The Uniphos 500 HA12 has 4 common potential-free relay contacts to control alarms or any other equipment. The on-board data logging allows easy access to historical data via a USB interface.
Uniphos 500 R2 Multichannel Rack Mountable Controller
Uniphos 500 R2 Multichannel Rack Mountable Controller
The building block design of the Uniphos 500 R2 provides the flexibility to build a system as small as 2 channels or as large as 16 channels. The Controller, apart from powering the transmitters, also provides a real time digital display of the gas concentrations, a variety of status alarms and the facility to transfer data to a computer.
Uniphos 500 W2 Dual Channel Controller
Uniphos 500 W2 Dual Channel Controller
The 500 W2 Dual Channel Controller is designed to accept analog 4-20 mA signal from one or two transmitters providing centralized monitoring of gas concentrations at one or two locations. The hi-viz LED display aids in providing a clear reading of the gas concentration even from a distance or in low light situations. The two-user settable alarm set points per channel and 3 relay contacts corresponding to each alarm condition provide a plethora of connection options. The additional RS-485 port enables easy data transfer from the controller to a PC.
Uniphos 500 W4 Quad Channel Controller
Uniphos 500 W4 Quad Channel Controller
The Uniphos 500 W4 is a wall mountable, quad channel microprocessor-based controller. The Hi-viz LED display provides a clear reading of the gas concentration even from a distance or in low light situations. The two-user settable alarm set points per channel and 3 relay contacts corresponding to each alarm condition provide a plethora of connection options.
Uniphos 500 WS Eight Channel Scanner
Uniphos 500 WS Eight Channel Scanner
The Uniphos 500 WS eight channel scanner provides an economical way to monitor up to 8 gas transmitters. The Hi-viz LED display provides a clear reading of the gas concentration even from a distance or in low light situations. The two-user settable alarm set points per channel and 3 common relay contacts corresponding to each alarm condition provide a plethora of connection options
Uniphos Ansidine Value Meter
Uniphos Ansidine Value Meter
The Uniphos p-Anisidine value meter is a light weight, low cost, microprocessor-based instrument tailor made for the measurement of p-anisidine value of edible oil. It operates on the principle of optical absorption to determine the anisidine value. The chemical analysis method of p-Anisidine Value determines the amount of aldehydes (principally 2-alkenals and 2,4-dienals) in animal and vegetable oils and fats. This easy-to-use battery-operated instrument features an intuitive user interface and has in-built data logging facility as standard.
Uniphos ASP-40 Air Sampling Pump and Accessories
Uniphos Envirotrack
Uniphos Envirotrack
The Uniphos Envirotrack is microprocessor based portable instrument custom made to measure the pollutants in the Ambient Air. It comes with an Air sampler where the sample air is scrubbed in a solution specific to the pollutant. The pollutant gas dissolves in the gas specific chemical and is further processed to produce a colored dye. The instrument measures the absorbance of light passed through this colored dye and relates it to the concentration of pollutants in ppb levels.
With datalogging included as standard and the presence of a USB interface, the user can easily transfer the stored data along with time and date to a computer.
Uniphos FFA Meter
Uniphos FFA Meter
Uniphos Free Fatty acids is an ideal instrument for the determination of acid value of edible Oil samples. The fatty acids in the oil get detached from the triglycerides during processing or improper storage. These free fatty acids contribute to oil rancidity and cause deterioration in flavour of the oil. The sample oil is first treated with a variety of reagents to create a colored dye. The instrument measures the absorbance of the light passed through this colored dye and relates it to the free fatty acids as % of Oleic acid. With datalogging included as standard and the USB interface present in the instrument allows the user to easily transfer the stored data along with time and date to a computer.
Uniphos HeadSpace Analyzer
Uniphos HeadSpace Analyzer
The Uniphos Headspace Analyser is a portable analyzer, ideal for quick and accurate measurement of gases used in Modified Atmosphere Packaging (MAP) and / or Controlled Atmosphere Packaging (CAP). The headspace analyzer helps in determining the success of CAP/ MAP packaging. It can only be used for collapsible type of packaging
Two variants of Headspace analyzer are available:
- Headspace Oxygen Analyzer – To measure the concentration of just Oxygen in CAP/MAP
- Headspace Gas Analyzer – To measure the concentration of Oxygen and Carbon Dioxide in CAP/MAP
The analyzer comprises of a sampling probe fitted with a syringe needle which can be used to pierce the collapsible packaging. It is equipped with a diaphragm pump which enables the instrument to draw the sample air from the packaging. It is equipped with an electrochemical sensor for O2 and an NDIR sensor for CO2 to deliver the most accurate result and unmatched performance possible. The OLED display enables the user to read the concentration levels even in the dark.
Uniphos Oil Spectrophotometer
Uniphos Oil Spectrophotometer
The Uniphos Oil Spectrophotometer is a light and compact portable microprocessor based nondispersive spectrophotometer tailormade for the analysis of metal elements in edible Oil. The sample oil is first treated with a variety of reagents to create a colored dye. The instrument measures the absorbance of the infrared light passed through this colored dye and calculates the concentration of metal impurities present in the Oil in ppm. The clear digital display and simple user interface makes the analysis easy to operate even by an ordinary technician. With datalogging included as standard and the USB interface present in the instrument allows the user to easily transfer the stored data along with time and date to a computer.
Uniphos Online Ammoniacal Nitrogen Analyzer
Uniphos Online Ammoniacal Nitrogen Analyzer
The presence of Nitrogen in the form of Ammonium/ Ammonia is termed as Ammoniacal Nitrogen in the influent/ sample
The Uniphos online Ammoniacal Nitrogen analyzer is an accurate, stable and fully automatic analyzer designed to measure Ammoniacal Nitrogen of process / surface water samples using an electrochemical sensor. No human intervention is required during the measurement as the analyzer is completely automated.
The inbuilt diagnostics feature provides an alarm if there are any faulty components or if the reagent falls below the minimum level. Equipped with a next generation touchscreen HMI for display and programming, the analyzer provides a variety of data communication options such as RS-485 MODBUS and industry standard 4-20 mA analog output
Uniphos Online COD Analyzer (Absorption Method)
Uniphos Online COD Analyzer
(Absorption Method)
Chemical Oxygen demand is defined as the amount of oxygen required for the oxidation of all the organic compounds present in a water sample.
The Uniphos online COD analyzer is a programmable, fully automatic analyzer which measures COD of waste / effluent water samples using a direct method of analysis. This direct method involves oxidation of the sample by potassium dichromate and measurement by absorption of Cr3+ ions. No human intervention is required during the measurement as the analyzer is completely automated.
The inbuilt diagnostics feature gives an alarm if there are any faulty components or if the reagent level goes below the minimum level. Equipped with a next generation touchscreen HMI for display and programming, the analyzer provides a variety of data communication options such as RS-485 MODBUS and industry standard 4-20 mA analog output
Uniphos Online COD Analyzer (Potentiometric Method)
Uniphos Online COD Analyzer
(Potentiometric Method)
Chemical Oxygen demand is defined as the amount of oxygen required for the oxidation of all the organic compounds present in a water sample.
The Uniphos online COD analyzer is a programmable, fully automatic analyzer which measures COD of waste / effluent water samples using a direct method of analysis. This direct method involves oxidation of sample by potassium dichromate and measurement by potentiometric titration. No human intervention is required during the measurement, as the analyzer is completely automated.
The inbuilt diagnostics feature gives an alarm if there are any faulty components or if the reagent level goes below the minimum level. Equipped with a next generation touchscreen HMI for display and programming, the analyzer provides a variety of data communication options such as RS-485 MODBUS and industry standard 4-20 mA analog output
Uniphos Online Total Cyanide Analyzer
Uniphos Online Total Cyanide Analyzer
Total Cyanide in effluent water refers to the sum of all cyanide-containing compounds, including free/ weak acid as well as dissociable and strong metal cyanide complexes.
The Uniphos online Cyanide analyzer is a reliable, fully automatic analyzer designed to measure the total cyanide of waste / effluent water samples by an ASTM 7511-09 method. The ASTM 7511-09 method involves acid digestion with UV irradiation and determination of total cyanide by amperometric method. The amperometric technique used is demonstrated to be free of analytical interferences and eliminates the use of hazardous reagents. No human intervention is required during the measurement as the analyzer is completely automated.
The inbuilt diagnostics feature gives an alarm if there are any faulty components or if the reagent level goes below the minimum level. Equipped with a next generation touchscreen HMI for display and programming, the analyzer provides a variety of data communication options such as RS-485 MODBUS and industry standard 4-20 mA analog output