Showing 37–48 of 54 results

Portable COD Analyzer with Digester

Portable COD Analyzer with Digester

Chemical Oxygen demand is defined as the amount of oxygen required for the oxidation of all the organic compounds present in the water sample.  

The portable, microprocessor based Uniphos COD analyzer operates on the non-dispersive absorption principle to measure COD of waste / effluent water samples. This easy to use battery operated analyzer features an easy to use intuitive interface and has in-built data logging facility as standard. The stored data can either be exported to a computer or printed as a report to a RS-232 printer.
A COD Digester is also provided with the COD analyzer for digestion of the water sample mixed with reagents. It is a robust instrument capable of accommodating 25 vials at a time. A PID controller in the digester ensures that all the samples are heated precisely to 150oC.  

FumiTrack Multiport with Expansion Module

FumiTrack Multiport with Expansion Module

Uniphos Multiport FumiTrack is a portable, programmable, fully automatic multi-port gas monitor for the periodic monitoring of Phosphine during Fumigation. Housed in a tough Pelican Storm Case, it provides superior protection in tough environments. The multi-port FumiTrack is capable of periodic measurement from up to 4 ports at user-settable intervals. With the addition of an 8-port expansion pack, monitoring can be expanded from up to 12 ports.  Equipped with the latest embedded and IoT technologies, the inbuilt GSM modem pushes data to the cloud and enables the user to remotely monitor gas concentration levels, with information like Cycle No., Date, Time, Site & Location. Once programmed, the FumiTrack will work automatically, without any human intervention, for the entire fumigation period, enabling the user to remotely monitor the fumigation from anywhere in the world.

FumiSense Pro PH3 – Lo

FumiSense Pro PH3 – Lo

FumiSense Pro-Lo is a handheld Phosphine monitor for monitoring phosphine levels outside the fumigated stack/ silo/ ship to check for leaks and to ensure the level of PH3 is less than the TLV. Equipped with an inbuilt air sampling pump and with the ability to measure PH3 up to 20 ppm, it is the perfect tool for this application. The backlit OLED display enables the user to read the instrument display even in the dark. With user settable datalogging features, the device logs gas concentration values with date, time and location.

Dust Analyzer

Dust Analyzer

An optical instrument designed to measure the concentration of dust or particulate matter suspended in the exhaust gas passing through a duct, stack, or flue; typically the exhaust gas from an industrial combustion process or air filtration system. 

Dust Analyzer uses the Innovative Dynamic Detection Principle (DDP) which measures fluctuations in the intensity of a light beam, using a folded beam Transceiver /Reflector arrangement. Increased particulate density in the stack causes the scattered light intensity to increase. When calibrated against reference standards, the intensity of this signal relates directly to the particulate concentration in the stack, and this can be used to display as a reading in mg/m³. 

Uniphos 500 W4 Quad Channel Controller

Uniphos 500 W4 Quad Channel Controller

The Uniphos 500 W4 is a wall mountable, quad channel microprocessor-based controller. The Hi-viz LED display provides a clear reading of the gas concentration even from a distance or in low light situations. The two-user settable alarm set points per channel and 3 relay contacts corresponding to each alarm condition provide a plethora of connection options. 

Uniphos Online COD Analyzer (Absorption Method)

Uniphos Online COD Analyzer
(Absorption Method)

Chemical Oxygen demand is defined as the amount of oxygen required for the oxidation of all the organic compounds present in a water sample.  

The Uniphos online COD analyzer is a programmable, fully automatic analyzer which measures COD of waste / effluent water samples using a direct method of analysis. This direct method involves oxidation of the sample by potassium dichromate and measurement by absorption of Cr3+ ions. No human intervention is required during the measurement as the analyzer is completely automated.
The inbuilt diagnostics feature gives an alarm if there are any faulty components or if the reagent level goes below the minimum level. Equipped with a next generation touchscreen HMI for display and programming, the analyzer provides a variety of data communication options such as RS-485 MODBUS and industry standard 4-20 mA analog output 

PH3 Dosimeter Tubes

PH3 Dosimeter Tubes

Uniphos Dosimeter tube is a device, very similar to gas detector tubes, that provides the Concentration-Time product (Dose) of phosphine during the entire fumigation durationBut, unlike normal detector tubes, phosphine enters the dosimeter tube by natural diffusion.  

FumiSense Pro PH3 – Hi (CO)

FumiSense Pro PH3 – Hi (CO)

FumiSense Pro–Hi is a handheld gas monitor for phosphine concentration measurement when CO is present along with phosphine, like in tobacco fumigation. Equipped with an inbuilt air sampling pump capable of drawing a sample from a distance of 30m and a sensor capable of measuring PH3 up to 2000 ppm, it is the perfect tool for this application. The backlit OLED display enables the user to read the instrument display even in the dark. With user settable datalogging features, the device logs gas concentration values with date, time and location.

Fluorescence Based SO2 Stack Gas Analyzer

Fluorescence Based SO2 Stack Gas Analyzer

The Uniphos Fluorescence Based SO2 Stack Gas Analyzer is a reliable instrument with high sensitivity and selectivity which is designed and developed to meet customer’s requirement for measuring the concentration of SO2 in PPM levels. Specific optical filters in the fluorescence cell in addition to moisture and hydrocarbon scrubbing systems ensures removal of any interferences making the analyzer highly specific for SO2 detection.  

The optical excitation of SO2 molecules results in fluorescence in the wavelength region typically between 240-420 nm and the fluorescence intensity is related to SO2 concentration.  

The Analyzer is equipped with the latest embedded and IOT technologies which enables the user to perform Auto/ Remote calibration. The analyzer comes with built in diagnostics and internal memory which can store the test results along with date and time. 

Uniphos 500 WS Eight Channel Scanner

Uniphos 500 WS Eight Channel Scanner

The Uniphos 500 WS eight channel scanner provides an economical way to monitor up to 8 gas transmitters. The Hi-viz LED display provides a clear reading of the gas concentration even from a distance or in low light situations. The two-user settable alarm set points per channel and 3 common relay contacts corresponding to each alarm condition provide a plethora of connection options

Uniphos Online Ammoniacal Nitrogen Analyzer

Uniphos Online Ammoniacal Nitrogen Analyzer

The presence of Nitrogen in the form of Ammonium/ Ammonia is termed as Ammoniacal Nitrogen in the influent/ sample 

The Uniphos online Ammoniacal Nitrogen analyzer is an accurate, stable and fully automatic analyzer designed to measure Ammoniacal Nitrogen of process / surface water samples using an electrochemical sensor. No human intervention is required during the measurement as the analyzer is completely automated.
The inbuilt diagnostics feature provides an alarm if there are any faulty components or if the reagent falls below the minimum level. Equipped with a next generation touchscreen HMI for display and programming, the analyzer provides a variety of data communication options such as RS-485 MODBUS and industry standard 4-20 mA analog output 

PH3 Gas Detector Tubes

PH3 Gas Detector Tubes

Gas Detector tubes, also known as colorimetric gas detection tubes, are sealed glass tubes filled with a sensing chemical. When air from inside or outside the fumigated space is drawn through the tube using the appropriate gas sampling pump, the sensing chemical inside changes color and forms a stain. The length of the stain thus formed is proportional to the gas concentration present at the point of sampling and can be easily read from the scale printed on the tube.  

Detector tubes enable the user to easily make on the spot measurements of Phosphine in the fumigated area. PH3 Tubes are available both in the lower concentration levels of 0.01 ppm, as well as the fumigation concentration levels of 400 to 5000 ppm. 

We offer a choice of both thick and thin tubes (KwikDraw and Uniphos) within our portfolio.