Showing 25–36 of 54 results

Single Port FumiTrack

Single Port FumiTrack

The Uniphos Single Port FumiTrack delivers unmatched performance for the detection and continuous monitoring of Hi and / or Lo concentration Phosphine during Fumigation. The unit draws gas samples at pre-determined intervals from inside the fumigation chamber / silo / container with a powerful inbuilt air sampling pump capable of drawing from upto 100m of tubing. Equipped with the latest embedded and IoT technologies, the inbuilt GSM modem pushes data to the cloud and enables the user to remotely monitor gas concentrations of the fumigant and ensure that they are at the right levels at all times during the entire fumigation process.  

FumiTrack Multiport with Expansion Module

FumiTrack Multiport with Expansion Module

Uniphos Multiport FumiTrack is a portable, programmable, fully automatic multi-port gas monitor for the periodic monitoring of Methyl Bromide during Fumigation. Housed in a tough Pelican Storm Case, it provides superior protection in tough environments. The multi-port FumiTrack is capable of periodic measurement from up to 4 ports at user-settable intervals. With the addition of an 8-port expansion pack, monitoring can be expanded from up to 12 ports.  Equipped with the latest embedded and IoT technologies, the inbuilt GSM modem pushes data to the cloud and enables the user to remotely monitor gas concentration levels, with information like Cycle No., Date, Time, Site & Location. Once programmed, the FumiTrack will work automatically, without any human intervention, for the entire fumigation period, enabling the user to remotely monitor the fumigation from anywhere in the world.

Peltier Based Sample Handling System

Peltier Based Sample Handling System

The Uniphos Peltier Cooled Probe is an advanced sample conditioning system to draw a gas sample from an emissions stack being monitored. Sample extraction and conditioning is an important part of all Continuous Emission Monitoring Systems (CEMS) and includes extracting the sample from the stack and maintaining the dew point of the sample at such a level that there is no condensation at any point until the concentration of the sample is measured. This ensures proper transport and measurement of sample concentrations.  

The Peltier Cooled Probe is a unique product which is based on an advanced hot and dry extractive technique where the sample is extracted and conditioned on the stack and transported to the analyzer using a non-heated sampling tube at ambient temperature. It consists of a stack mountable system which includes a heated probe, a short, heated sampling line and a Peltier cooled sample conditioning module, all integrated in a single enclosure. Using a Peltier Cooled Probe reduces the length of the heated sampling line to less than half a meter, bringing down the operating cost many times. 

Uniphos Ansidine Value Meter

Uniphos Ansidine Value Meter

The Uniphos p-Anisidine value meter is a light weight, low cost, microprocessor-based instrument tailor made for the measurement of p-anisidine value of edible oil. It operates on the principle of optical absorption to determine the anisidine value. The chemical analysis method of p-Anisidine Value determines the amount of aldehydes (principally 2-alkenals and 2,4-dienals) in animal and vegetable oils and fats. This easy-to-use battery-operated instrument features an intuitive user interface and has in-built data logging facility as standard. 

Uniphos TSS probe with Controller

Uniphos TSS probe with Controller

The Uniphos TSS probe utilizes optical spectroscopic technique to determine the presence of suspended solids in Industrial wastewater, surface water, etc.  Utilizing an IR light source and IR detector to determine the TSS, as well as a solenoid valve for auto purging/ cleaning the sensor, the instrument provides an accurate and affordable solution for TSS monitoring in wastewater.

Equipped with a next generation touchscreen HMI controller for display and programming the unit, the probe provides a variety of data communication options such as RS-485 MODBUS and industry standard 4-20 mA analog output. 

Uniphos ASP-40 Air Sampling Pump and Accessories

The Uniphos ASP-40 pump is a light weight and rugged piston and barrel type of air sampling pump that creates a vacuum in the pump barrel causing it to draw an accurate volume of sample air through the connected gas detector tube. The integrated end-of-stroke indicator changes colour to indicate the completion of sampling. The Uniphos ASP-40 pump is easy to operate and is designed for use with the entire Uniphos gas detector tube range.

Uniphos Envirotrack

Uniphos Envirotrack

The Uniphos Envirotrack is microprocessor based portable instrument custom made to measure the pollutants in the Ambient Air. It comes with an Air sampler where the sample air is scrubbed in a solution specific to the pollutant. The pollutant gas dissolves in the gas specific chemical and is further processed to produce a colored dye. The instrument measures the absorbance of light passed through this colored dye and relates it to the concentration of pollutants in ppb levels.  
With datalogging included as standard and the presence of a USB interface, the user can easily transfer the stored data along with time and date to a computer. 

FumiTrack – Single Port

FumiTrack – Single Port

TheUniphosSingle PortFumiTrackdelivers unmatched performancefor the detection and continuous monitoring of Methyl Bromide during Fumigation.The unit draws gas samples at pre-determined intervals from inside the fumigation chamber / silo / container with a powerful inbuilt air sampling pump capable of drawing fromupto100m of tubing. Equipped with the latest embedded and IoT technologies, the inbuilt GSM modem pushes data to the cloud and enables the usertoremotelymonitor gas concentrations of the fumigantand ensure that they are at the right levels at all times during the entire fumigation process. 

Remote Calibration

Remote Calibration

Remote calibration is the process of remotely triggering either zero or span calibration for a gas analyzer through a web portal. The remote calibration feature in the Uniphos CEMS not only enables access to the analyzer remotely but also assists in performing various activities like zeroing, calibration and validation of the analyzer remotely.

Uniphos FFA Meter

Uniphos FFA Meter

Uniphos Free Fatty acids is an ideal instrument for the determination of acid value of edible Oil samples.  The fatty acids in the oil get detached from the triglycerides during processing or improper storage. These free fatty acids contribute to oil rancidity and cause deterioration in flavour of the oil. The sample oil is first treated with a variety of reagents to create a colored dye. The instrument measures the absorbance of the light passed through this colored dye and relates it to the free fatty acids as % of Oleic acid. With datalogging included as standard and the USB interface present in the instrument allows the user to easily transfer the stored data along with time and date to a computer. 

UV-VIS COD-TSS Probe with Controller

UV-VIS COD-TSS Probe with Controller

Operating on the principle of absorption spectroscopic technique to measure COD, BOD & TSS in Industrial wastewater, surface water, etc., the probe is equipped with a solenoid valve which is capable of auto purging/ cleaning the sensor. The Light source and UV detector present in the instrument provide an accurate measurement of COD, BOD, & TSS in wastewater.  
 
Equipped with a next generation touchscreen HMI controller for display and programming the unit, the probe provides a variety of data communication options such as RS-485 MODBUS and industry standard 4-20 mA analog output. The analyser is also programmed to display BOD value of known matrix 

Boreal Gasfinder3-MC

Boreal Gasfinder3-MC

The Gasfinder3-MC is an all-in-one field mountable multi-channel analyzer which can detect two different target gases for fast leak detection and ambient monitoring.

For more information click here.