Solo C3 – Carbon Monoxide Detector Tester
The Solo C3 carbon monoxide (CO) detector tester spray is designed for use in conjunction with the Solo 330 dispenser. Used in this controlled manner, the canister safely tests a CO detector by introducing a measured amount of CO gas to the sensor, whilst maintaining concentration levels below the toxic threshold. The Solo C3 tester is non-flammable and is supplied in a non-hazardous pressurised canister.
Introduces CO gas to the detector sensor
Non-flammable
To be used in conjunction with the Solo 330 dispenser
A measured amount of CO gas is delivered in a controlled manner
Concentration levels below the user danger level
Supplied in a non-hazardous pressurised 250ml canister
Please note: Some carbon monoxide detectors require a low level of CO present over a long period of time. It is unlikely that the Solo C3 will be suitable for testing these types of detectors.
Solo C6 – Hand-held Carbon Monoxide Detector Tester
Designed for use with domestic carbon monoxide (CO) detectors, the Solo C6 is a hand-held tester spray that does not require specialist equipment, such as dispensers. It is supplied with an applicator straw, which introduces CO to the detector sensor in a controlled manner.
For testing domestic carbon monoxide detectors
Hand-held - no need for specialist dispensing equipment
Supplied complete with applicator straw
Introduces CO to the detector sensor in a controlled manner
Contents: approx. 4 litres
Non-flammable, compressed gas
Due to the nature of the contents, the aerosol feels very lightweight
Please note: For testing FireAngel CO-9B and CO-9X carbon monoxide detectors, please use the FireAngel Easy Gas tester spray.
Solo Domestic Smoke and Carbon Monoxide Alarm Tester Kit
The Solo domestic smoke and carbon monoxide (CO) alarm tester kit is ideal for applications such as rented accommodation, where the landlord is responsible to ensure alarms are functional upon changeover of tenancy. Supplied with Solo A10 and Solo C3 aerosols, the large dispenser introduces smoke or CO without flooding the alarms. The 1.13m extension access pole ensures alarms at normal ceiling height can be reached without the need for ladders.
Allows "functional" smoke and CO alarm testing to be carried out
Extension access pole enables reach of alarms at normal ceiling height
Kit includes
Solo 332 Large Smoke Dispenser
Solo 101 Extension Access Pole
Solo A10 Smoke Detector Tester (150ml)
Solo C3 Carbon Monoxide Detector Tester (250ml)
Ideal for use by facilities management and maintenance companies
Large smoke dispenser suitable for alarms up to 17.7cm/7" in diameter
Introduces the activating element without flooding the alarms
Suitable for most domestic smoke and CO alarms
Testifire 1000 Smoke/Heat Detector Tester – Head Unit
Testifire products offer multi-sensor testing capabilities. The Testifire 1000-001 replacement smoke/heat detector tester can be used with your existing Solo telescopic or extension pole and helps remove the need for expensive scaffolding when testing detectors that are out of reach. The unit is supplied with the required smoke capsule.
Enables trained personnel to carry out "functional" testing on devices that are out of reach
Capable of testing both heat and smoke detectors
User friendly programmable interface
Also suitable for aspirating smoke detector systems
Powered by Solo 770 battery batons (sold separately)
Ensures compliance with the Safe Working at Height Regulations 2005
Does not require stored pressure cylinders - smoke generated as needed from capsule
Increased efficiency offers potential time saving of 45 minutes per day for users
Please note: This listing is for the tester head unit ONLY. For a full kit including battery batons and charger, please see the Testifire 1002 Smoke/Heat Detector Testing Kit.
Testifire 1002 Smoke/Heat Detector Testing Kit
The Testifire 1002 Smoke/Heat detector testing kit offers amazing time saving benefits for those providing commercial detector testing services. With automated test initiation and bespoke, programmable test cycles, the Testifire 1002 kit offers substantial long term time and cost saving benefits. This kit also features a clearing function to remove any residual smoke or heat from the sensor quickly, reducing the time for each individual sensor test.
Kit includes:
Testifire 1000 smoke/heat detector tester
TS3 smoke capsule
Two Solo battery batons
Solo 727 fast charger
Automated infra-red test initiation
User friendly programmable interface
Multiple test modes and test cycles
Highly customisable test sequences including simultaneous testing
Colour coded LED user feedback
Automatic power-off feature after 5 minutes of inactivity to extend battery life
No pressurised containers needed - stimuli created on demand
Testifire 2000 Smoke/Heat/CO Detector Tester – Head Unit
The Testifire range of products offer the best value multi-sensor testing equipment available. Testifire's 2000-001 replacement smoke/heat/CO detector tester head is designed to be used with your existing Solo telescopic or extension pole and helps remove the need for expensive scaffolding when testing detectors on high ceilings. The technologically advanced 2000 series allows for functional testing of not only smoke and heat sensors, but also carbon monoxide detectors. Testifire products generate the required sensor stimuli as and when needed. This removes the need to transport pressurised containers containing smoke or carbon monoxide to site, presenting a massive advantage.
Enables trained personnel to carry out "functional" testing on devices that are out of reach
User friendly programmable interface
Capable of testing smoke, heat and carbon monoxide (CO) detectors
Also suitable for aspirating smoke detector systems
Powered by Solo 770 battery batons (sold separately)
Ensures compliance with the Safe Working at Height Regulations 2005
Does not require stored pressure cylinders - smoke and CO generated as needed from capsules
Increased efficiency offers a potential time saving of up to 45 minutes per day for users
Please note: This listing is for the tester head unit ONLY. For a full kit including battery batons and charger, please see the Testifire 2002 Smoke/Heat/CO Detector Testing Kit.
Testifire 2001-001 Smoke/Heat/CO Detector Testing Kit
This product has been designed to revolutionise commercial fire alarm testing. The Testifire 2002 kit allows trained personnel to carry out "functional" testing on remote smoke, heat and carbon monoxide (CO) sensors without the need for scaffolding, harnesses or ladders. This presents the obvious safety benefits, but also allows users to save an estimated 45 minutes per day by removing the need to set up platforms etc. The device creates the necessary stimuli as needed, meaning there is zero waste, and also offers a clearing function meaning you can move on from having tested a device confident in the knowledge it is clear and ready to go.
Kit includes:
Testifire 2000 Smoke/Heat/CO detector tester
TS3 smoke capsule
TC3 carbon monoxide capsule
Two solo battery batons
Solo 727 fast charger
User friendly programmable interface
Automated infra-red test initiation
Multiple test modes and test cycles
Highly customisable test sequences including simultaneous testing
Automatic power-off feature after 5 minutes of inactivity to extend battery life
No pressurised containers needed- both smoke and CO created on demand
Testifire 6002 6m Smoke/Heat Detector Testing Kit
The Testifire 6002 smoke/heat detector testing kit offers an upgraded range of 6 metres which allows climb-free access to detectors on higher ceilings. Removing the need for extensive scaffolding creates an amazing time saving benefit for those carrying out commercial detector testing. With automated test initiation and bespoke, programmable test cycles, the Testifire 6002 kit offers massive long term time and cost saving benefits for those carrying out "functional" testing on devices that are hard to reach by other means. This premium kit is supplied complete with a universal detector removal tool and protective storage/carry bag as standard.
Kit includes:
Testifire 1000 smoke/heat detector tester
TS3 smoke capsule
Two solo battery batons
Solo 727 fast charger
Solo universal detector removal tool
Solo 100-001 fibreglass 4.5m telescopic access pole
Solo 601-001 protective carrying/storage bag
Automated infra-red test initiation
User friendly programmable interface
Multiple test modes and test cycles
Highly customisable test sequences including simultaneous testing
Colour coded LED user feedback
Automatic power-off feature after 5 minutes of inactivity to extend battery life
No pressurised containers needed - stimuli created on demand
Testifire 6202 6m Smoke/Heat/CO Detector Testing Kit
The Testifire 6202 smoke/heat/CO detector testing system offers an extended reach of 6 metres, greatly improving it's range compared to the standard version. The kit is modular, meaning it can be used to access devices at standard heights as well as enabling climb-free access to detectors on higher ceilings. Removing the need for extensive scaffolding creates amazing time saving benefits for those carrying out commercial detector testing. With automated test initiation and bespoke, programmable test cycles, the Testifire 6202 kit offers a versatile system that offers long term time and cost saving benefits. This premium kit is supplied complete with a universal detector removal tool and protective storage/carry bag, making this the complete system.
Kit includes:
Testifire 2000 smoke/heat/CO detector tester
TS3 smoke capsule
TC3 carbon monoxide capsule
Two solo battery batons
Solo 727 fast charger
Solo universal detector removal tool
Solo 100-001 fibreglass 4.5m telescopic access pole
Solo 601-001 protective carrying/storage bag
Automated infra-red test initiation
User friendly programmable interface
Multiple test modes and test cycles
Highly customisable test sequences including simultaneous testing
Colour coded LED user feedback
Automatic power-off feature after 5 minutes of inactivity to extend battery life
Allows trained personnel to carry out "functional" testing on smoke, heat and CO sensors
No pressurised containers needed- stimuli created on demand for smoke and CO sensors