Product Code | NC365SMGE |
---|---|
Alternative Product Codes | Solo371-001 |
Brand | Solo 365 |
Weight | 0.50kg |
Product Datasheets | Solo 365 Smoke Generator Instructions |
Solo 365 Replacement Smoke Generator
This replacement Smoke Generator for the Solo 365 smoke detector tester is designed to produce on-demand test smoke in conjunction with the ES3 Smoke Cartridge. As with most core components of the Solo 365, the Smoke Generator was created with the user in mind and is easy to replace should its performance drop for any reason.
Designed for use only with Solo 365 equipment
Works with the ES3 Smoke Cartridge
Automatically creates smoke when the Solo 365 cup is over a detector head
On-demand, 5-second smoke cycles prevent wastage and detector contamination
Easy to install, field-replaceable design – no manufacturer service required
Test more detectors in less time by carrying spares instead of going back to the van
Description
Related products
Solo 423 & 424 – Mains Powered Heat Detector Testers
The Solo mains powered heat detector testers are designed specifically for checking heat detectors using a genuine and safe heat source. Available in two voltage versions, the mains powered heat detector testers are supplied with a 5m (16ft) cable and are suitable for use on fixed temperature, rate-of-rise and combination detectors up to 90 °C (194 °F). The Solo telescopic poles allow the tester to access heat detectors at height, therefore eliminating the need for ladders or scaffolding.
Provides detectors with a genuine and safe heat source
Designed in accordance with the Construction Regulations 1996 and the Electricity at Work Regulations 1989
Suitable for the majority of modern heat detectors
Can be used on fixed temperature, rate-of-rise and combination detectors up to 90 °C/194 °F
Rapid activation times
Available in two versions:
Solo 423 - 110/120V
Solo 424 - 220/240V
Lightweight and easy to use
Supplied with a 5m/16ft cable as standard
Compatible with Solo telescopic poles for testing at height
Solo Domestic Smoke and Carbon Monoxide Alarm Tester Kit
The Solo domestic smoke and carbon monoxide (CO) alarm tester kit is ideal for applications such as rented accommodation, where the landlord is responsible to ensure alarms are functional upon changeover of tenancy. Supplied with Solo A10 and Solo C3 aerosols, the large dispenser introduces smoke or CO without flooding the alarms. The 1.13m extension access pole ensures alarms at normal ceiling height can be reached without the need for ladders.
Allows "functional" smoke and CO alarm testing to be carried out
Extension access pole enables reach of alarms at normal ceiling height
Kit includes
Solo 332 Large Smoke Dispenser
Solo 101 Extension Access Pole
Solo A10 Smoke Detector Tester (150ml)
Solo C3 Carbon Monoxide Detector Tester (250ml)
Ideal for use by facilities management and maintenance companies
Large smoke dispenser suitable for alarms up to 17.7cm/7" in diameter
Introduces the activating element without flooding the alarms
Suitable for most domestic smoke and CO alarms
Solo 610 – Protective Storage Bag
This protective storage/carrying bag is designed for use with Solo and Testifire smoke, heat and CO detector testing systems including head units, battery batons, chargers and aerosols. Ideal for use by technicians when visiting a site, the protective bag allows the Solo equipment to be carried with ease in a tidy and compact manner for a professional look. Helps to protect equipment from damage during transit and when not in use Provides a compact and tidy storage solution Designed for use with Solo and Testifire smoke, heat and CO detector testing products Suitable for storing head units, battery batons, chargers and aerosols A separate bag for access poles is including as standard Provides a professional look for when a technician attends site
Solo 365 Universal Charging Kit
The Solo 365 Universal Charging Kit allows engineers to charge their Solo 365 batteries from almost any power source. Containing the correct type of USB cable for the battery and CE Marked transformer, the selection of changeable international plug faces enable even the most far-reaching companies to benefit from the new Solo 365 detector testing equipment. As it uses a standard USB connection this kit even works with most portable power banks and laptops, allowing the Solo 365 to be recharged almost anywhere.
Designed for use with the Solo 365 Battery Pack
Works with most USB power sources and a wide range of international power supplies
Supplied with transformer block to provide optimum voltage and current
Simple click-on plug face design
No large "power brick" required, reducing bulk and weight for transportation
Please note: The Solo 365 Head & Core Components Kit includes a Universal Charger Kit as standard.
Solo 365 Adaptor for ASD Systems
Designed for use with the Solo 365 smoke detector testing head unit, this firm rubber attachment facilitates quick and easy testing of ASD – aspirating smoke detection – systems by directing and containing the synthetic smoke to a small area directly over the sampling holes. The Solo 365's delayed start function combined with the adaptor's directed and contained flow of smoke provide engineers with a quick and efficient test cycle, cutting down on wastage. Due to its thin, flexible, and lightweight construction, the Solo 372 aspirating smoke detection system adaptor can easily be carried around sites and swapped out when needed, eliminating time spent moving between tests and the van to change equipment.
No-fuss functional testing of aspirating smoke detection systems
Designed for use only with Solo 365 equipment
Quick and easy to fit while on the job
Small and lightweight – can be kept on hand at all times
Controlled smoke delivery for less wastage and more efficient testing
Allows testing of both ASD and point detectors with a single, portable device
Works with the Solo 365's delayed start and manual purge options
Slimline design enables access to awkwardly positioned detectors
Please note: the Solo 365 head unit is shown for illustration purposes only and must be purchased separately.
Solo 101 – Extension Access Pole
The Solo 101 extension access pole, designed for use on its own or in conjunction with a Solo telescopic pole, allows for detector testing equipment to be used at normal ceiling height or up to a maximum working height of 9 metres. The extension access pole negates the need for ladders or expensive scaffolding and therefore ensures that alarm technicians fully comply with the Safe Working at Height Directive.
Pole length: 1.13m
Can be used:
On its own to reach normal ceiling height
In conjunction with a Solo telescopic access pole for additional height
With Testifire and Solo testing devices
Ideal for use with Solo detector equipment including:
Solo 330 Smoke Dispenser
Solo 461 Cordless Heat Detector Test Kit
Solo 423 & 424 Mains Powered Heat Detector Testers
Solo 200 Universal Detector Removal Tool
Ensures compliance with the Safe Working at Height Directive
Allows for "functional" testing to be carried out
Testing equipment can be used at heights up to 9 meters using three extension poles and the Solo 100 or 108 access poles
Non-conductive glass fibre construction protects engineer from inadvertent shorts
Solo 365 Spare Battery Pack
The Solo 365 smoke detector tester is not compatible with the battery batons used for other testing equipment, such as the Testifire or Solo 400 series, and instead uses a new battery pack that fits in the head of the unit. Utilising high-capacity Lithium Ion technology, the new Solo 365 battery pack can be recharged by a standard MicroUSB cable from almost any power source while the small and lightweight design means spares can easily be carried around on site.
Designed for use only with Solo 365 equipment
Available individually and in packs of 4
Small, lightweight design makes carrying spares far easier than traditional Solo battery batons
High-capacity Lithium Ion technology
Rechargeable via MicroUSB from almost any power source with the Universal Charging Kit
Test more detectors in less time by carrying spares instead of going back to the van
Solo 365 Field Service Pack
Unlike other electronic detector testing systems, the Solo 365 does not require manufacturer refurbishment or servicing when any single component breaks, as the high-use parts are available for replacement by the user. The field service pack contains all user-replaceable components for the Solo 365 smoke detector test head, allowing engineers to carry spares everywhere they go to almost completely eliminate downtime due to damaged or worn-out equipment. Containing a cup and membrane, smoke generator module, and a battery, this kit includes almost everything needed to keep a Solo 365 in working order.
Designed for use only with Solo 365 equipment
Easy to install, field-replaceable design – no service requirement
Test more detectors in less time by carrying spares instead of going back to the van
The field service pack contains:
1x Cup & Membrane
1x Smoke Generator
1x Lithium Ion Battery Pack
Small, lightweight component designs make carrying spares far easier
Reduced downtime due to damaged equipment
Please note: ES3 smoke cartridges and the universal charging kit are not included in this pack.