Baloon Fixed Flow Regulator

Mainly used for calibration and filling of weather balloons. Balloon regulator has a unique outlet with a flow rate of 15 L/Mn and can be used on cylinders with standard c10 connection.
SPECIFICATIONS
Inlet Pressure: 
70 bar
Outlet Flow: 
15 L/Mn
Inlet Connection: 
C10-5/8” x 18 UNF-M
Outlet Connection: 
Balloon connection
Material: 
Brass
Warranty: 
1 year

Push Button Fixed Flow Regulator

Push Button Regulator comes with a ON/OFF button on its top as preventive measure for accidental loss of gas and is mainly used for Bump Testing.
SPECIFICATIONS
Inlet Pressure: 
70 bar
Outlet Flow: 
0.5 L/Mn & 1.0 L/Mn
Inlet Connection: 
C10-5/8” x 18 UNF-M
Outlet Connection: 
Taper Shank Adaptable to Polyurethane Tube
Material: 
Brass & Stainless Steel
Warranty: 
1 year

Bump Test Fixed Flow Regulator

Bump test is a functional test of a gas monitor. This regulator is used for calibration and working of Bump test for known quantity gas.
SPECIFICATIONS
Inlet Pressure: 
70 bar
Outlet Flow: 
0.5 L/Mn
Inlet Connection: 
C10-5/8” x 18 UNF-M
Outlet Connection: 
1/8” BSP or NPT-F
Material: 
Brass
Warranty: 
1 year

Push Lever Fixed Flow Regulator

The trigger regulator comes with lever which can be operated in two ways, when the lever is pushed it works as an ON/OFF switch whereas when the lever is pulled upwards the regulator gives continuous flow of gas.
SPECIFICATIONS
Inlet Pressure: 
70 bar
Outlet Flow: 
0.5 L/Mn & 1.0 L/Mn
Inlet Connection: 
C10-5/8” x 18 UNF-M
Outlet Connection: 
Barbed Outlet
Material: 
Brass & Stainless Steel
Warranty: 
1 year

Combination Regulator

Combination Regulator is compatible with standard C10 connection refillable cylinders. The unique design of this regulator allows it to act like a valve and regulator when needed. It consists of ON/OFF knob with pressure gauge to determine the cylinder volume and a gas refiling port on top on of the regulator.
SPECIFICATIONS
Inlet Pressure: 
100 bar
Outlet Flow: 
0.1 to 7 L/Mn
Inlet Connection: 
1/14” UNS
Outlet Connection: 
Barbed Outlet
Material: 
Aluminium
Warranty: 
1 year

S Flow Regulator

An Economical Alternative to the fixed flow regulator and comes with adjustable flow rates. The S-Flow regulator comes with ON/OFF knob and a rotameter to indicate flow rates.
SPECIFICATIONS
Inlet Pressure: 
70 bar or 35 bar
Outlet Flow: 
0.25L/Mn, 0.5 L/Mn, 0.75L/Mn, 1.0 L/Mn
Inlet Connection: 
C10-5/8” x 18 UNF-M or Aerosol
Outlet Connection: 
Barbed Outlet
Material: 
Brass
Warranty: 
1 year

Duo Fixed Flow Regulator

The Duo flow regulator is designed to have a button on top for temporary release of gas if the button is pressed down to prevent accidental loss of gas and a rotating cap for situations where continuous flow of gas is required and the regulator is needed to be in on position.   Both mechanisms are easy to use for outlet flow rates of 0.5 L/Mn and 1.0 L/Mn
SPECIFICATIONS
Inlet Pressure: 
70 bar
Outlet Flow: 
0.5 L/Mn & 1.0 L/Mn
Inlet Connection: 
C10-5/8” x 18 UNF-M
Outlet Connection: 
Barbed connection & Taper Shank adaptable to Polyurethane tube.
Material: 
Brass
Warranty: 
1 year

Single Stage Regulator

Single-stage gas pressure regulators reduce cylinder pressure to delivery or outlet pressure in a single or one step. Its one of the safest means to reduce pressure and has large supply pressure effect. The Regulator comes with gauge upto 315 Bar and bottom connection made of stainless steel.
SPECIFICATIONS
Inlet Pressure: 
150 bar max
Outlet Pressure: 
0-2 bar max
Outlet Flow: 
15 L/Mn
Inlet Connection: 
1/4” NPT Female- Adaptor to C10 valve
Outlet Connection: 
¼” NPT female or 1/8” NPT Female
Regulator Inlet Port: 
¼” NPT Female – Adaptor to c10 valve or 1/8” NPT Female
Material: 
Stainless Steel and Aluminium
Warranty: 
1 year

Fixed Flow Regulator

Fixed Flow Regulator is manufactured to give various fixed flow rates and is compatible with all gas cylinders with a C10 connection. It is one of the most common regulators used in the world of gas Calibration and comes with a wide range of flows that are set as per your need. Suitable for Oxygen as all parts are made of Brass and range from 0.5 L/Mn to 25 L/Mn.
SPECIFICATIONS
Inlet Pressure: 
70 bar
Outlet Flow: 
0.5 L/Mn to 25.0 L/Mn
Inlet Connection: 
C10 ( 5/8″ x 18 UNF -M )
Outlet Connection: 
Barbed connection
Material: 
Brass / Stainless Steel
Warranty: 
1 year

Standard Demand Flow Regulator

Demand Flow Regulator is used mainly for docking stations and regulator is set to open only under vacuum of 3-inch water column which gives a flow rate of 0-3 L/Mn. The regulator comes in both standard C10 connection and High-Pressure NPT connection.
SPECIFICATIONS
Inlet Pressure: 
70 bar or 200 bar
Outlet Flow: 
0-3 L/Mn
Inlet Connection: 
C10-5/8” x 18 UNF-M or 1/4“ NPT F for the high Pressure
Outlet Connection: 
Barbed Outlet
Material: 
Brass or Stainless Steel
Warranty: 
1 year

Fixed Flow Regulator NPT

Fixed Flow Regulator is manufactured to give various fixed flow rates and is compatible with all gas cylinders with a NPT connection.
SPECIFICATIONS
Inlet Pressure: 
200 bar
Outlet Flow: 
0.5 L/Mn & 1.0 L/Mn
Inlet Connection: 
1/4“ NPT F
Outlet Connection: 
Barbed connection
Material: 
Stainless Steel
Warranty: 
1 year

Trigger Fixed Flow Regulator

The trigger regulator is designed to provide aerosol capability, this regulator can be used with 34L and 58L aluminium cylinders. The trigger can be used for dispensing gas at flow rate of 0.5L/Mn. And can be flipped upwards into on position for continuous flow of gas.
SPECIFICATIONS
Inlet Pressure: 
70 bar
Outlet Flow: 
0.5 L/Mn
Inlet Connection: 
C10-5/8” x 18 UNF-M
Outlet Connection: 
6mm Straight tube
Material: 
Brass
Warranty: 
1 year