OPTIFLUX 4100

Electromagnetic flowmeter for standard applications with abrasive and aggressive liquids

  • Chemically resistant, for liquids (>5 μS/cm) with solid content (≤10%)
  • Up to +180°C / +356°F
  • Flange: DN2.5…1200 / ⅒…48", max. PN40 / ASME Cl 1500
  • 4…20 mA, pulse, frequency, status, HART®

OPTIFLUX 4300

Electromagnetic flowmeter for advanced process and custody transfer (CT) applications

  • High accuracy (±0.2%), certified for custody transfer
  • For low conductivity media (>1 μS/cm) and high solid contents (≤70%)
  • Flange: DN2.5…3000 / ⅒…120", max. PN40 / ASME Cl 1500
  • 3 x 4…20 mA, HART®,Modbus, FF, Profibus-PA/DP, PROFINET

POWERFLUX 4300

Electromagnetic flowmeter for nuclear applications

  • Designed and tested for industrial nuclear environments
  • With resistant ETFE or PFA liner materials
  • Flange: DN25…1000 / 1…40"
  • 3 x 4…20 mA, HART®, Modbus, FF, Profibus-PA/DP, PROFINET

POWERFLUX 5030

Electromagnetic flowmeter for nuclear applications

  • Designed and tested for industrial nuclear environments
  • With high-tech ceramic tube (DN2.5…100 / 110…4") for very aggressive and abrasive fluids
  • Free of programmable electronic components
  • 4…20 mA

OPTIFLUX 5100

Electromagnetic flowmeter for demanding applications with aggressive and abrasive media

  • With chemically resistant ceramic tube for liquids with solid content (≤10%)
  • Up to +180°C / +356°F
  • Flange: DN2.5…300 / ⅒…12", max. PN40 / ASME Cl 300; Wafer: max. DN100 / 4"
  • 4…20 mA, pulse, frequency, status, HART®

OPTIFLUX 5300

Electromagnetic flowmeter for advanced process and master meter applications

  • Highest accuracy (±0.15%), with ceramic tube for aggressive and abrasive liquids (≤70% solid content) up to +180°C / +356°F
  • CT: OIML R117, MI-005 etc.
  • Flange: DN2.5…300 / 1/10…12", max. PN40 / ASME Cl 300; Wafer: DN100 / 4"
  • 3 x 4…20 mA, HART®, Modbus, FF, Profibus-PA/DP, PROFINET

POWERFLUX 5300

Electromagnetic flowmeter for nuclear applications

  • Designed and tested for industrial nuclear environments
  • With high-tech ceramic tube for very aggressive and abrasive fluids
  • Space-saving wafer design: DN2.5…100 / 1⁄10…4"
  • 3 x 4…20 mA, HART®, Modbus, FF, Profibus-PA/DP, PROFINET

BATCHFLUX 5500

Electromagnetic flowmeter for demanding volumetric filling applications for a wide range of container sizes

  • High accuracy measurement in process batching as well as cold or hot filling of conductive liquids, e.g. milk, fruit drinks with solid content, detergents etc.
  • With ceramic measuring tube and sintered electrodes for applications up to 16 bar / 232 psi
  • Flow tube conforms to EC1935/2004, FDA, GB 4806; 3A certified up to DN25 / 1"
  • Frequency output integrated

BATCHFLUX 3100

New

Electromagnetic flowmeter for the volumetric filling of common container sizes

  • The most compact filling mag meter in the market for filling of conductive liquids, e.g. water, carbonized soft drinks etc.
  • Lightweight, economical design with ceramic flow tube for applications up to 8 bar / 116 psi
  • The DN15 / ½″ ceramic tube conforms to EC1935/2004, FDA, GB 4806
  • Frequency output integrated

OPTIFLUX 6050

Electromagnetic flowmeter for basic hygienic applications

  • Cost-effective flow measurement in the food sector
  • Meter size: DN2.5…150 / ⅒…6" (3A, EHEDG etc.)
  • Many hygienic fittings
  • 4…20 mA, pulse, frequency, status, HART®, Modbus

OPTIFLUX 6100

Electromagnetic flowmeter for hygienic standard applications

  • Reliable dosing and filling in the food sector
  • Meter size: DN2.5…150 / ⅒…6"
  • Hygienic fittings and certifications
  • 4…20 mA, pulse, frequency, status, HART®

OPTIFLUX 6300

Electromagnetic flowmeter for advanced hygienic applications

  • High accuracy (±0.2%), for exact dosing or filling in the food sector
  • Meter size: DN2.5…150 / ⅒…6" (3A, EHEDG certified)
  • Many hygienic fittings
  • 3 x 4…20 mA, HART®, Modbus, FF, Profibus-PA/DP, PROFINET

OPTIFLUX 7300

Electromagnetic flowmeter for low conductivity liquids (≥0.05 μS/cm)

  • Ceramic tube with non-wetted electrodes for extremely adhesive and abrasive media
  • Hygienic and vacuum resistant
  • Flange or wafer version: DN25…100 / 1…4", max. PN40 / ASME Cl :300
  • 3 x 4…20 mA, HART®, Modbus, FF, Profibus-PA/DP, PROFINET

OPTIPROBE

Electromagnetic insertion-type flowmeter for water and wastewater applications

  • With fixed or flexible installation length for hot tapping
  • 0…+100°C; max. 16 barg
  • For pipes ≥DN80 / 3"
  • 3 x 4…20 mA, HART®, Modbus, FF, Profibus-PA/DP, PROFINET

DWM 2000

Electromagnetic insertion-type flowmeter for flow monitoring of conductive media

  • Ideal for liquids, pastes and slurries (≥20μS/cm), suitable for immersed applications (IP68)
  • -25…+150°C / -13…+302°F; up to 25 barg / 360 psig
  • For pipes DN25…400 / 1…16", optional >DN400 / 16"
  • 3-wire, 4…20 mA

OPTISONIC 3400

Ultrasonic flowmeter for liquid process applications

  • Accurate 3-path meter: large dynamic range, maintenance-free, no pressure loss
  • Cryogenic (-200°C/-328°F) and HT (+250°C/+482°F) versions; viscosities up to over 1000 cSt
  • Flange: DN25…3000 / 1…120", max. PN200 / ASME Cl 1500; also weld-ends
  • 3 x 4…20 mA, HART®, Modbus, FF, Profibus-PA/DP

OPTISONIC 3400 District Heating

Ultrasonic flowmeter for district heating applications

  • 3-path meter for thermal energy measurement and heated water
  • CT: OIML R75, MID MI-004 (Class 1, 2, 3)
  • Flange: DN25…2000 / 1…80", max. PN40 / ASME Cl 300
  • Max. +180°C / +356°F

OPTISONIC 4400 HP

Ultrasonic flowmeter for high pressure liquids

  • 2-path meter for flow measurement of condensate, high pressure feedwater, spray water or water injection
  • Operating pressure up to 490 bar / 7107 psi
  • Max. DN1000 / 40", up to ASME Cl 4500
  • 3 x 4…20 mA, HART®7, Modbus, FF, Profibus-PA/DP

OPTISONIC 4400 HT

Ultrasonic flowmeter for high temperature liquids

  • 2-path meter for flow measurement of thermal oil, boiler feed water, crudes and hot feed flows in refineries
  • Up to +600°C / +1112°F
  • Flange: max. DN1000 / 40"
  • 3 x 4…20 mA, HART®7, Modbus, FF, Profibus-PA/DP

OPTISONIC 6300 P

Ultrasonic clamp-on flowmeter for temporary flow measurement of liquids

  • Portable, battery-powered meter, for on-site verification of process flows or inline meters at any location
  • -40…+120°C / +248°F
  • For pipes DN15…1500 / ½…60"
  • With data logger and USB interface for data transfer

OPTISONIC 6300

Ultrasonic clamp-on flowmeter for flow measurement of liquids

  • Stationary device, for installation at any location without process interruption or need to cut pipes
  • Up to +200°C / +392°F
  • Robust stainless steel sensor rail for pipes DN15…4000 / ½…160"
  • 4…20 mA, HART®7, Modbus

OPTISONIC 7300

Ultrasonic flowmeter for natural gas, process gas and utility gas applications

  • 2-path meter, for standard volume flow metering, independent of media properties
  • No maintenance, no pressure loss, large dynamic range
  • Flange: DN50…1000 / 2…40", max. PN450 / ASME Cl 2500; also weld-in connections
  • 3 x 4…20 mA, HART®, Modbus, FF

OPTISONIC 7300 Biogas

Ultrasonic flowmeter for biogas, landfill and sewage gas applications

  • 1- or 2-path meter for low pressure biogas (dry or wet) with a high CO2 content
  • Integrated gas volume correction and methane content measurement
  • Lap joint flange: DN50…200 / 2…8", max. PN10 / ASME Cl 150
  • Large turndown ratio (100:1)

ALTOSONIC V12

Ultrasonic flowmeter for custody transfer (CT) measurement of gases

  • 12-chord meter, for high accuracy flow metering of natural gas
  • CT: OIML R137 (class 0.5), MI-002, AGA9 etc.
  • Many variants, extensive CBM diagnostics free of charge
  • Flange: DN100…1600 / 4…64"; max. PN450 / ASME Cl 2500

OPTISONIC 8300

Ultrasonic flowmeter for superheated steam and high temperature gases

  • 2-path meter with optional mass flow and enthalpy calculation
  • For steam billing, boiler or power plant monitoring (up to +620°C / +1148°F)
  • DN100…1000 / 4…40"; max. PN250 / ASME Cl 2500
  • Large turndown ratio (60:1)

ALTOSONIC 5

Ultrasonic flowmeter for custody transfer (CT) measurement in upstream and midstream applications

  • Multipath inline meter for crudes, refined products, cryogenic media and chemicals
  • CT: OIML R117, API compliant
  • Flange: 4…24"; max. ASME Cl 600
  • -200…+250°C / -328…+482°F

ALTOSONIC III

Ultrasonic flowmeter for custody transfer (CT) measurement of liquid hydrocarbons

  • Multipath inline flowmeter for light crude oils and refined products
  • CT: OIML R117, MI-005, API, GOST etc.
  • Flange: 2…40"; max. ASME Cl 900
  • -200…+220°C / -328…+364°F

ALTOSONIC V

Product discontinued

Ultrasonic flowmeter for custody transfer (CT) measurement in upstream and midstream applications

  • Multipath inline flowmeter for a wide range of liquid hydrocarbons
  • CT: OIML R117, MI-005, API, GOST etc.
  • Flange: 4…24"; max. ASME Cl 1500
  • -200…+250°C / -328…+482°F

H250 M40

Variable area flowmeter for liquids and gases

  • Modular design: from mechanical indicator to 4…20 mA/HART®7, FF, Profibus-PA and totalizer
  • Any installation position: vertical, horizontal or in fall pipes
  • Flange: DN15…150 / ½…6"; also NPT, G, hygienic connections, etc.
  • -196…+400°C / -320…+752°F; max. 1000 barg / 14500 psig

H250 M8

Variable area flowmeter for liquids and gases

  • Mechanical or with electronic bargraph indicator (4…20 mA/HART®)
  • Flange: DN15…25 / ½…1"; also NPT, G, hygienic connections, etc.
  • -40…+200°C / +392°F; max. 145 barg / 2102 psig

DK37 M8

Variable area flowmeter for advanced low liquid and gas flows

  • Mechanical or with electronic indicator (4…20 mA/HART®)
  • Sturdy metal design: stainless steel or alloy
  • Thread: G¼, ¼ NPT; others
  • -40…+150°C / +302°F; max. 220 barg / 3190 psig

DK32/34

Variable area flowmeter for low liquid and gas flows

  • Compact mechanical indicator, optional 4…20  mA/HART®7, MIN/MAX switches and needle valve
  • Sturdy metal design: stainless steel or alloy
  • Thread: G¼, ¼ NPT, etc.
  • -40…+200°C / +392°F, max. 220 barg / 3190 psig

DK46/47/48/800

Variable area flowmeter for low flow gas or liquid applications and sample flow monitoring

  • Glass tube with analogue scale, valve and switches
  • For low flows from ≥0.04 l/h or ≥0.1 GPH
  • G and NPT threads; others on request
  • -5…+100°C / +23…+212°F; max. 10 barg / 145 psig

VA40

Variable area flowmeter for basic applications

  • With glass tube, MIN/MAX switches and 4…20 mA
  • Low pressure loss for gas applications
  • Flange: DN15…50 / ½…2"; also NPT, G, hygienic connections, etc.
  • -20…+100°C / -4…+212°F; max. 10 barg / 145 psig

VA45

Variable area flowmeter for low pressure gas applications

  • Glass tube with easy-to-read scale
  • For use in gas supply lines of furnaces, protective gas or heating systems
  • Flange: DN15…40 / ½…1½"; also NPT, G, hose connection
  • -20…+100°C / -4…+212°F; max. 1 barg / 14.5 psig

K20

Variable area flowmeter for basic water applications

  • Plastic tube with scale and a MIN/MAX switch
  • Very cost-effective flow indication
  • Thread: G½, G1, G2; or adhesive sleeve
  • 0…+100°C / +32…+212°F; max. 10 barg / 145 psig