Dräger PointGard 2200
Dräger Polytron® 5200 CAT
The Dräger Polytron® 5200 CAT is a cost-effective explosion-proof transmitter for the detection of flammable gases in the lower explosion limit (LEL). It uses a catalytic bead DrägerSensor® Ex that will detect most flammable gases and vapours. A 3-wire 4 to 20 mA analogue output with relays makes it compatible with most control systems.
Dräger Polytron® 8200 CAT
The Dräger Polytron® 8200 CAT is an advanced explosion-proof transmitter for the detection of flammable gases in the lower explosion limit (LEL). It uses a catalytic bead DrägerSensor® Ex that will detect most flammable gases and vapours. In addition to a 3-wire 4 to 20-mA analogue output with relays it also offers HART®, Modbus and Fieldbus protocols, making it compatible with most control systems.
Dräger VarioGard 3200 CAT Transmitter
Dräger PIR 7000
Dräger PointGard 2700
The Dräger PointGard 2700 is a self-contained gas detection system for the continuous area monitoring of flammable hydrocarbon gases and vapors in ambient air. PointGard 2700’s rugged, water-resistant housing comes complete with a horn and strobes, a built-in power supply, and external relays. It is compatible with a remotely mounted Dräger PIR 7000 Type 334 or Type 340 infrared gas sensor.
Dräger Polytron® 5310 IR
The Dräger Polytron® 5310 IR is a cost effective explosion-proof transmitter for the detection of flammable gases in the lower explosion limit (LEL). It uses an infrared DrägerSensor® IR that can be configured for methane, propane, or ethylene. A 3-wire 4 to 20-mA analogue output with relays makes it compatible with most control systems.
Dräger Polytron® 5700 IR
Dräger Polytron® 8310 IR
The Dräger Polytron® 8310 IR is an advanced explosion proof transmitter for the detection of combustible gases in the lower explosion limit (LEL). It uses an infrared DrägerSensor® IR that can be configured for methane, propane or ethylene. Besides a 3 wire 4 to 20 mA analogue output with relays, it also offers HART®, Modbus and Fieldbus protocols making it compatible with most control systems.
Dräger Polytron® 8700 IR
The Dräger Polytron® 8700 IR is an advanced explosion proof transmitter for the detection of combustible gases in the lower explosion limit (LEL). It uses a high performance infrared Dräger PIR 7000 sensor, which will quickly detect most common hydrocarbon gases. Besides a 3 wire 4 to 20 mA analogue output with relays, it also offers HART®, Modbus and Fieldbus making it compatible with most control systems.
Dräger VarioGard® 2300 IR
Dräger VarioGard® 3300 IR Transmitter
GasSecure GS01
MetCam Gas Camera
Refrigerant Transmitter
SF6 Transmitter
Catalytic Bead DrägerSensor®
The DrägerSensor® ... DQ detects flammable gases and vapours such as hydrogen. Due to the double-detector compensation method, the catalytic sensor is particularly long-term stable. The wire mesh at the gas inlet serves as a flame barrier. So it ensures explosion protection at the same time short response time.
Electrochemical DrägerSensor®
Dräger FS-5000
Dräger HPS 3500
Dräger PEX 1000
The Dräger PEX 1000 is a converter module that converts the mV signals of the Dräger Polytron® SE Ex DQ sensing heads into mA signals and sends them to a control unit like the Dräger REGARD® 2410. Together with the Dräger Polytron® SE Ex DQ, the PEX 1000 fulfils the conditions set down for primary explosion protection.
Dräger PSD 3000
Dräger VarioGard Relay Module
Dräger RVP 3900 Visualization panel
Dräger RVP 7000
Dräger RVP 7000 is a visualisation panel for data management and graphical representation of your Dräger REGARD® 7000 control system. Tables, alarm messages and icons provide an overview of measured values, and the statuses of gas warning systems. The panel is simple to operate using touch functions and gesture commands.
Dräger VVP 1000
Dräger PointGard 2100
Dräger Polytron® 3000
Dräger Polytron® 5100 EC
The Dräger Polytron® 5100 EC is a cost-effective explosion-proof transmitter for the detection of toxic gases or oxygen in standard applications. It uses a high performance plug-and-play electrochemical DrägerSensor® to detect a specific gas. A 2- or 3-wire 4 to 20 mA output with relays makes it compatible with most control systems.
Dräger Polytron® 6100 EC WL
The Dräger Polytron 6100 EC WL is a wireless transmitter for continuous monitoring of toxic gases and oxygen. The instrinsically safe and SIL2-rated transmitter features completely wireless signal transmission and power supply. The internal battery pack allows the transmitter to operate continually for up to 24 month. This makes the Polytron a flexible and cost efficient solution for plant expansions, upgrades or new installations.
Dräger Polytron® A500
Dräger Polytron® C300
The Dräger Polytron® C300 is a sensing head specifically designed for permanently capturing the ammonia concentration in livestock environments. The integrated DrägerSensor® NH3-AL is the only electrochemical sensor for continuous long-term ammonia measurement under the harsh conditions in animal houses.