OPTISENS ORP 8500
Potentiometric ORP sensor for water and wastewater applications
- For use with analytical transmitter
- Process connection: PG13.5
- -1500…+1500 mV; Max. +70°C / +158°F; 2 bar / 30 psi
- Glass sensor with platinum electrode and ceramic diaphragm
OPTISENS ORP 8590
Potentiometric ORP sensor for water and wastewater applications
- For use with analytical transmitter
- Process connection: ¾ NPT (male)
- -2000…+2000 mV; Max. +80°C / +176°F; 6.9 bar / 100 psi
- Sensor with CPVC body, platinum electrode, ceramic diaphragm and Pt100 temperature sensor
OPTISENS ADO 2000
Amperometric oxygen sensor for water and wastewater applications
- For use with analytical transmitter
- For immersion or insertion
- 0…20 mg/l; Max. +50°C / +122°F; 6 bar / 87 psi
- With stainless steel sensor body, rugged PTFE membrane, exchangeable electrode cartridge and temperature compensation
OPTISENS ODO 2000
Optical oxygen sensor for water and wastewater applications
- For use with analytical transmitter
- For immersion or insertion
- 0…20 mg/l; Max +50°C / +122°F; 6 bar / 87 psi
- With rugged PVC sensor body, available with spray cleaning nozzle (immersion version)
SMARTPAT PH 1590
Potentiometric pH sensor for potable, process or treated water applications
- 2-wire loop powered, 4…20 mA/HART® 7, for direct connection to a PCS
- Process connection: ¾ NPT (male)
- 0…14 pH; Max. +80°C / +176°F; 6.9 bar / 100 psi
- With CPVC sensor body, ceramic diaphragm and Pt1000 for temperature compensation
SMARTPAT PH 8150
Potentiometric pH sensor for chemicals and industrial wastewater applications
- 2-wire loop powered, 4…20 mA/HART® 7, for direct connection to a PCS
- Process connection: PG13.5
- 0…14 pH; Max. +130°C / +266°F; 12 bar / 174 psi
- Glass sensor with open diaphragms and Pt1000 for temperature compensation
SMARTPAT PH 8320
Potentiometric pH sensor for water and wastewater applications
- 2-wire loop powered, 4…20 mA/HART® 7, for direct connection to a PCS
- Process connection: PG13.5
- 0…14 pH; Max. +70°C / +158°F; 10 bar / 145 psi
- Glass sensor with PTFE diaphragm and Pt1000 for temperature compensation
SMARTPAT PH 8530
Potentiometric pH sensor for pure water and low conductivity media (>2 μS/cm)
- 2-wire loop powered, 4…20 mA/HART® 7, for direct connection to a PCS
- Process connection: PG13.5
- 0…14 pH; Max. +80°C / +176°F; 12 bar / 174 psi
- Glass sensor with 3 ceramic diaphragms and Pt1000 for temperature compensation
SMARTPAT PH 8570
Potentiometric pH sensor for food, beverage and pharmaceutical applications
- 2-wire loop powered, 4…20 mA/HART® 7, for direct connection to a PCS
- Process connection: PG13.5
- 0…14 pH; Max. +140°C / +284°F (SIP/CIP); 12 bar / 174 psi
- Autoclavable glass sensor with ceramic diaphragm and Pt1000 for temperature compensation
OPTISENS PH 8100
Potentiometric pH sensor for chemicals, industrial wastewater and low conductivity media (>2 μS/cm)
- For use with analytical transmitter
- Process connection: PG13.5
- 0…14 pH; Max. +130°C / +266°F; 10 bar / 145 psi
- Glass sensor with 2 open diaphragms and Pt100 for temperature compensation
OPTISENS PH 8300
Potentiometric pH sensor for wastewater, surface and process water applications
- For use with analytical transmitter
- Process connection: PG13.5
- 0…14 pH; Max. +70°C / +158°F; 10 bar / 145 psi
- Glass sensor with PTFE diaphragm and optional Pt100 for temperature compensation
OPTISENS PH 8390
Potentiometric pH sensor for municipal and industrial wastewater applications
- For use with analytical transmitter
- Process connection: ¾ NPT (male)
- 0…14 pH; Max. +80°C / +176°F; 6.9 bar / 100 psi
- With CPVC sensor body, PTFE diaphragm and Pt100 for temperature compensation
OPTISENS PH 8500
Potentiometric pH sensor for potable water applications
- For use with analytical transmitter
- Process connection: PG13.5
- 0…14 pH; Max. +70°C / +158°F; 2 bar / 30 psi
- Glass sensor with ceramic diaphragm and optional Pt100 for temperature compensation
OPTISENS PH 8590
Potentiometric pH sensor for water and wastewater applications
- For use with analytical transmitter
- Process connection: ¾ NPT (male)
- 0…14 pH; Max. +80°C / +176°F; 6.9 bar / 100 psi
- With CPVC sensor body, ceramic diaphragm and Pt100 for temperature compensation
OPTISENS PH 9100
Potentiometric pH sensor for lower conductivity water applications (>20 μS/cm)
- For use with analytical transmitter
- Process connection: PG13.5
- 0…14 pH; Max. +100°C / +212°F; 1 bar / 14 psi
- Liquid electrolyte glass sensor with open glass sleeve diaphragm
OPTISENS PH 9500
Potentiometric pH sensor for lower conductivity water applications (>50 μS/cm)
- For use with analytical transmitter
- Process connection: PG13.5
- 0…14 pH; Max. +100°C / +212°F
; 1 bar / 14 psi - Liquid electrolyte glass sensor with 3 ceramic diaphragms
SMARTPAT PH 2390
Potentiometric pH sensor for municipal and industrial wastewater applications
- 2-wire loop powered, 4…20 mA/HART® 7, for direct connection to a PCS
- Process connection: ¾ NPT (male)
- 0…14 pH; Max. +80°C / +176°F; 6.9 bar / 100 psi
- With PPS sensor body, PTFE diaphragm and Pt1000 for temperature compensation
OPTISYS SLM 2100
Optical sludge level measuring system for sedimentation profile measurement and continuous tracking of sludge blanket
- Integrated electronics with 2 x 4…20 mA, 3 relays, limit switches
- 3 measurement modes: profile, sludge blanket/ fluff levels, zone tracking; automatic change of modes possible
- 0.1…30 g/l; max. 10 m / 32.8 ft
- Optional automatic flush cleaning unit for low maintenance
OPTISENS TSS 2000
Optical total suspended solids sensor for wastewater applications
- For use with MAC 100 analytical transmitter
- For immersion
- 0…4 AU, 0…18.5 g/l (sludge); max. +70°C / +158°F; 1 bar / 14 psi
- Robust stainless steel sensor using single beam (180° NIR LED) principle, with optical sapphire glass windows
OPTISENS TSS 3000
Optical total suspended solids sensor for wastewater applications
- For use with MAC 300 analytical transmitter
- Process connection: 1¼ NPT (male)
- 0…2.5, 10 or 25 g/l (sludge); Max. +85°C / +185°F; 10 bar / 145 psi
- PP sensor using 4-beam alternating light principle, no optical windows, glass free
OPTISENS TSS 7000
Optical total suspended solids sensor for hygienic applications
- For use with MAC 300 analytical transmitter
- Process connection: Tri-Clamp 2″, 3″; VARIVENT® N
- 0…1.5, 20 or 40% milk fat; Max. +85°C / +185°F; 10 bar / 145 psi
- PP or PVDF sensor using 4-beam alternating light principle, no optical windows, glass free
MAC 100
Liquid analytical transmitter for measurements with sensors of the OPTISENS portfolio
- Output: 3 x 4…20 mA, 3 relays (mechanical)
- Input: max. 2 x sensor, 2 x temperature
- -15…+55°C / +5…+131°F (ambient)
- Robust housing for wall-mount installation
OPTISYS TUR 1060
Optical turbidity measuring system for potable water applications
- 4-wire, 4…20 mA, 2 alarm relays or Modbus via RS485; built-in data logger
- For online bypass installation
- 0…100/1000 NTU/FNU; max. +50°C / +122°F; 7 bar / 101 psi
- 90° scattered infrared light (ISO 7027) or white light (US EPA 180.1)
OPTISENS TUR 2000
Optical turbidity sensor for water and wastewater applications
- For use with analytical transmitter
- For immersion or insertion
- 0…4/40/400 NTU/FNU; Max. +50°C / +122°F; 6 bar / 87 psi
- 90° scattered light (NIR-LED) measurement acc. to ISO 7027
OPTISYS TSS 4050
Total suspended solids system for hygienic applications
- 4-wire, 4…20 mA, with head-mounted transmitter
- Process connection: PG13.5
- Max.: 3 AU, 6 OD, 13000 FAU, 13000 FTU, 3250 EBC, 26.65 g/l; +90°C / +194°F; 10 bar / 145 psi
- Hygienic stainless steel design, CIP/SIP cleanable
OPTISYS TSS 3050
Total suspended solids system for hygienic applications
- 4-wire, 4…20 mA, with head-mounted transmitter
- Process connection: G½ for hygienic adapters
- Max.: 3 AU, 6 OD, 13000 FAU, 13000 FTU, 3250 EBC, 26.65 g/l, +90°C / +194°F; 10 bar / 145 psi
- Hygienic stainless steel design, CIP/SIP cleanable
OPTISYS TSS 2050
Total suspended solids system for hygienic applications
- 4-wire, 4…20 mA, with head-mounted transmitter
- Process connection: PG13.5
- Max.: 500 EBC, 2000 FAU, 5.0 g/l, 0.4% TS; +90°C / +194°F; 10 bar / 145 psi
- Hygienic stainless steel design, CIP/SIP cleanable
OPTISYS TSS 1050
Total suspended solids system for hygienic applications
- 4-wire, 4…20 mA, with head-mounted transmitter
- Process connection: G½ for hygienic adapters
- Max.: 500 EBC, 2000 FAU, 5.0 g/l, 0.4% TS; +90°C / +194°F; 10 bar / 145 psi
- Hygienic stainless steel design, CIP/SIP cleanable
MAC 300
Liquid analytical transmitter for measurements with OPTISENS TSS, pH/ORP and COND sensors
- Output: max. 6 x 4…20 mA, max. 6 x relay or optional Modbus
- Input: up to 3 x sensor
- -20…+50°C / +4…+122°F (ambient)
- Robust housing for wall-mount or panel-mount installation