OPTIBAR DSD 3100
OPTIBAR DSD 3110
OPTIBAR DSD 3210
OPTIBAR DSD 3220
OPTIBAR DSP 2000
Diaphragm seal with threaded connection or open measuring flanges
- Direct or capillary tube attachment to OPTIBAR PM pressure transmitters
- Thread: G ½ (male), ½ NPT (male, female); Open measuring flanges up to DN50 / 2"
- Up to +400°C / +752°F (with capillary tube)
- Wetted materials for aggressive, corrosive, viscous, solidifying or abrasive media
OPTIBAR DSP 3000
Diaphragm seal with flange design and optional extension
- For direct or capillary tube attachment to OPTIBAR PM pressure transmitters
- Flange: DN50…100 / 2…4"; max. PN63 / ASME Cl 300
- Up to +400°C / +752°F (with capillary tube)
- Wetted materials for aggressive, corrosive, viscous, solidifying or abrasive media
OPTIBAR PM 3050
OPTIBAR DP 3050
OPTIBAR PC 5060
Pressure transmitter for advanced process pressure and level applications
- Robust design, with corrosion and abrasion resistant ceramic diaphragm
- 25 mbar…100 bar / 0.73…1450 psi; max. +150°C / +302°F
- Various threads, flanges, hygienic and other connections
- 2-wire, 4…20 mA, HART®, FF, Profibus-PA, Bluetooth®
OPTIBAR PM 5060
Pressure transmitter for process pressure and level applications
- Rugged design with fully welded metallic diaphragm suited to high pressure ranges and hygienic requirements
- 100 mbar…1000 bar / 1.45…14500 psi
- Various threads, flanges, aseptic and other connections
- 2-wire 4…20 mA/HART®, FF, Profibus-PA, Bluetooth®
OPTIBAR DP 7060
Differential pressure transmitter for flow, level, differential pressure, density and interface measurements
- High performance DP transmitter with integrated line pressure measurement
- Measuring range: 30 mbar…16bar / 0.44…232 psi; Line pressure: up to 400 bar / 5800 psi
- Reference accuracy of ±0.065%
- 2-wire, 4…20 mA/HART®, FF, Profibus-PA, Bluetooth®
OPTIBAR P 1010
OPTIBAR P 2010
OPTIBAR PT 2000
Flow nozzle
Venturi tube
Engineered primary element for DP flow measurement of liquids, gases and steam with the lowest residual pressure loss
- Machined or welded design (internally machined) according to EN ISO 5167, ASME MFC3
- Lowest residual pressure loss of all DP elements
- Only short inlet/outlet runs required
- From basic to special wet gas applications and high pressure conditions
Cone meter
Engineered primary element for DP flow measurement in applications with limited installation space
- Meter run with integrated cone and single taps according to EN ISO 5167
- Rugged solution for difficult media and harsh operating conditions, e.g. in oil and gas applications
- Designed for large diameters (up to 24″), demanding flow profiles, high pressures and temperatures