Showing 73–96 of 414 results

DW 181

Mechanical flow controller for clean liquids

  • Flow indication without power supply
  • Up to 30,000 l/h or 132.09 GPM (US)
  • Thread: G¾…2, ¾…2 NPT
  • -40…+300°C / -40…+570°F; max. 40 barg / 580 psig

DW 182

Mechanical flow controller for clean liquids

  • Flow indication without power supply
  • Up to 30,000 l/h or 132.09 GPM (US)
  • Flange: DN15…65 / ½…2½", max. PN40 / ASME Cl 300
  • -40…+300°C / -40…+570°F

DW 183

Mechanical flow controller for clean liquids

  • Flow indication without power supply
  • Up to 250,000 l/h or 1101 GPM (US)
  • Flange: DN65…200 / 3…8", max. PN16 / ASME Cl 150
  • -40…+300°C / -40…+570°F

DW 184

Mechanical flow controller for clean liquids

  • Flow indication without power supply
  • For applications with large pipes of any size
  • Flange: ≥DN150 /6", max. PN40 / ASME Cl 300
  • -40…+300°C / -40…+570°F

OPTIMASS 6400

Coriolis mass flowmeter for advanced process applications

  • High accuracy (±0.05% flat), for cryogenic to HT media (-200…+400°C / -328…+752°F); maintains operation over a wide range of gas fractions and complex flow conditions (EGMTM)
  • SIL 2/3; CT: OIML R117, R137, MI-005, MI-002; API, AGA; hygienic certifications
  • Flange: DN10…300 / ½…12", max. PN 160 / ASME Cl 1500
  • 3 x 4…20 mA, HART®7, Modbus, FF, Profibus-PA/DP, PROFINET, EtherNet/IP™, Bluetooth®

OPTIMASS 2400

Coriolis mass flowmeter for highest capacity bulk measurement

  • For gases and liquids up to 4,600 t/h; maintains operation over a wide range of gas fractions and complex flow conditions (EGMTM)
  • CT: OIML R117, MI-005, MI-002; API and AGA compliant
  • Flange: DN100…400 / 4…16", max. PN160 / ASME Cl 1500
  • 3 x 4…20 mA, HART®7, Modbus, FF, Profibus-PA/DP, PROFINET, EtherNet/IP™, Bluetooth®

OPTIMASS 7400

Coriolis mass flowmeter for advanced process applications

  • High accuracy (±0.1%), for viscous, aggressive or shear-sensitive media; maintains operation over a wide range of gas fractions and complex flow conditions (EGMTM)
  • CT: OIML R117, MI-005; API; hygienic certifications
  • Flange: DN10…100 / ½…4", max. PN100 / ASME Cl 600; others
  • 3 x 4…20 mA, HART®7, Modbus, FF, Profibus-PA/DP, PROFINET, EtherNet/IP™, Bluetooth®

OPTIMASS 1400

Coriolis mass flowmeter for universal applications and process control

  • Mass, density and volume flow of gases and liquids; maintains operation over a wide range of gas fractions and complex flow conditions (EGMTM)
  • Also certified for hygienic use
  • Flange: DN15…100 / ½…4", max. PN100 / ASME Cl 600; many hygienic fittings
  • 3 x 4…20 mA, HART®7, FF, Profibus-PA/DP, Modbus, PROFINET, EtherNet/IP™, Bluetooth®

OPTIMASS 3400

Coriolis mass flowmeter for low flow and dosing applications

  • High accuracy (±0.1%) for gases and liquids >0.3 kg/h / 0.01 lb/min; maintains operation over a wide range of gas fractions and complex flow conditions (EGMTM)
  • Standard pressure rating up to 300 bar / 4351 psi
  • Flange: DN15 / 1/2"; also thread and clamp connections
  • 3 x 4…20 mA, HART®7, Modbus, FF, Profibus-PA/DP, PROFINET, EtherNet/IP™, Bluetooth®

OPTIMASS 7010

Coriolis mass flowmeter for advanced applications and process control

  • Single straight tube for mass, density and volume flow of viscous, aggressive or shear-sensitive media
  • Also certified for hygienic use
  • Flange: DN10…100 / ½…4", max. PN100 / ASME Cl 600; others
  • Integrated Modbus; optional EtherNet/IP™ interface

OPTIMASS 3010

Coriolis mass flowmeter for low flow and dosing applications

  • Mass, density and volume flow of liquids and gases (>0.3 kg/h / 0.01 lb/min)
  • Standard pressure rating up to 300 bar / 4351 psi
  • Flange: DN15 / ½"; thread, clamp, etc.
  • Integrated Modbus; optional EtherNet/IP™ interface

OPTIMASS 1010

Coriolis mass flowmeter for universal applications and process control

  • For mass, density and volume flow of liquids and gases up to +130°C / +266°F
  • Also certified for hygienic use
  • Flange: DN15…100 / ½…4", max. PN100 / ASME Cl 600; many hygienic fittings
  • Integrated Modbus; optional EtherNet/IP™ interface

OPTIBATCH 4011

Coriolis mass flowmeter for linear and rotating filling machines

  • High accuracy batching of conductive and non-conductive liquids
  • Meter size: DN8…15 (FDA, EC1935/2004 etc.)
  • Many hygienic fittings
  • Integrated Modbus

OPTIGAS 4010

Coriolis mass flowmeter for gas dispenser applications

  • High accuracy for CNG and LPG up to 70 kg/min / 155 lb/min
  • Thread: ¾ NPT (female); up to 350 bar / 5075 psi
  • Integrated Modbus, no separate converter
  • EtherNet/IP™ interface

OPTIBAR DP 7060with orifice plate

DP flowmeter for volume flow measurement of liquids, gases and steam

  • For basic to very demanding aggressive, abrasive or viscous media
  • Up to +400°C / +752°F; max. 160 bar / 2320.1 psi (line pressure)
  • Flange: DN50…600 / 2…24"
  • 2-wire 4…20 mA/HART®, FF, Profibus-PA

OPTIBAR DP 7060with orifice meter run assembly

DP flowmeter for volume flow measurement of liquids, gases and steam

  • For small line sizes
  • Up to +400°C / +752°F; max. 160 bar / 2320.1 psi; (line pressure)
  • Sizes: DN15…100 / ¾…2"
  • 2-wire 4…20 mA/HART®, FF, Profibus-PA

OPTIBAR DP 7060with averaging pitot tube

DP flowmeter for volume flow measurement of liquids, gases and steam

  • From basic to engineered versions
  • Cryogenic to high temperatures possible (-200…+1000°C / -328…1832°F); max. 160 bar / 2320.1  psi (line pressure)
  • Line sizes from DN50…2000 / 2…80" (larger on request)
  • 2-wire 4…20 mA/HART®, FF, Profibus-PA

OPTIBAR DP 7060with cone meter

DP flowmeter for volume flow measurement of liquids, gases and steam

  • For basic to engineered versions for challenging flow conditions
  • -270…+400°C / -454…+752°F possible; max. 160 bar / 2320.1 psi
  • Size: optional DN100…3000 / 4…120"
  • 2-wire 4…20 mA/HART®, FF, Profibus-PA

OPTIFLUX 1050

Electromagnetic flowmeter for basic applications with conductive liquids

  • Cost-effective flow measurement of liquids (≥5 μS/cm) up to +120°C / +248°F
  • Extra isolation of electronics for use in high humidity areas
  • Wafer-style design: DN10…150 / ⅜…6", max. PN40 / ASME Cl 300
  • 4…20 mA, pulse, frequency, status, HART®, Modbus

OPTIFLUX 1100

Electromagnetic flowmeter for general applications with conductive liquids

  • Economical flow measurement of liquids (≥5 μS/cm) with solid content (≤10%)
  • -25…+120°C / -13…+248°F
  • Wafer-style design: DN10…150 / ⅜…6", max. PN40 / ASME Cl 300
  • 4…20 mA, pulse, frequency, status, HART®

OPTIFLUX 1300

Electromagnetic flowmeter for OEM applications, dosing systems and compact skids

  • Economical flow measurement of liquids (≥5 μS/cm) with solid content (≤70%)
  • -25…+120°C / -13…+248°F
  • Wafer-style design: DN10…150 / ⅜…6", max. PN40 / ASME Cl 300
  • 3 x 4…20 mA, HART®, Modbus, FF, Profibus-PA/DP, PROFINET

OPTIFLUX 2050

Electromagnetic flowmeter for basic water and wastewater applications

  • Liner materials resistant to low concentrated chemicals
  • With extra isolation of electronics for use in high humidity areas
  • Flange: DN25…1200 / 1…48", max. PN40 / ASME Cl 300
  • 4…20 mA, pulse, frequency, status, HART®, Modbus

OPTIFLUX 2100

Electromagnetic flowmeter for all standard water and wastewater applications

  • Chemically resistant liner materials
  • Compact version up to IP69, remote version IP68
  • Flange: DN25…1200 / 1…48", max. PN40 / ASME Cl 300
  • 4…20 mA, pulse, frequency, status, HART®

AF-E 400

Electromagnetic flowmeter for utilities and industrial automation

  • Flow measurement of conductive liquids, e.g. coolants, cold/hot water, chemicals, etc.
  • Best-in class temperature range, accuracy, pressure drop and flow range
  • Ultra-compact design for parallel installation and tight spaces
  • 4…20 mA, pulse, frequency, Modbus, IO-Link