SMARTBASE
Product discontinued
Database for all SMARTPAT PH sensors
- Storage function for configuration and calibration data
- Handling of sensor data during offline calibration and configuration
- With module for statistical analysis of historical data
- With PACTware™ software philosophy
SD 200
Multiparameter indicator for analytical and other parameters
- Loop powered, 4…20 mA, with signal calibration feature (passive), HART® 7
- Indication of multiple units (analytical values, temperature, pressure etc.)
- With LCD display for wall or rack mount
- Power supply: 15…30 VDC (loop powered), 2 V voltage drop
OPTIBRIDGE
USB interface cable for offline calibration and configuration of SMARTPAT sensors
- For direct communication between a 2-wire or passive 4…20 mA HART® device and a PC
- With PACTware™ FDT/DTMs for each parameter
- Different adapter cables available
- No external power supply required
SJB 200
Junction box for connecting SMARTPAT to HART® devices
- Internal connection: Connecting terminals for HART® handhelds
- External connection: M12 connector
- With die-cast aluminium housing (IP66)
- -40…+65°C / -40…+149°F (ambient)
SENSOFIT RAM 5810
Automatic retractable assembly for harsh chemical and water treatment applications
- For use with ∅12 / 225 mm or ∅0.47 / 8.9″ sensors; for exchange, calibration and cleaning without process interruption
- Sensor connection: PG13.5; Process connection: DN32, 40, 50 / 2″
- Insertion length: 107 mm / 4.21″
- Max. +140°C / +284°F and 16 bar / 232 psi
SENSOFIT RAM 5830
Automatic retractable assembly for hygienic applications in the food, beverage and pharmaceutical industry
- For use with ∅12 / 225 mm or ∅0.47 / 8.9″ sensors; for exchange, calibration and cleaning without process interruption
- Sensor connection: PG13.5; Process connection: INGOLD G1¼ (coupling nut)
- Insertion length: 107 mm / 4.21″
- Max. +140°C / +284°F and 16 bar / 232 psi
SENSOFIT FLOW 1000 T
Flow-through assembly for chemical and water treatment applications
- For use with OPTISENS IND 1000 inductive conductivity sensor
- Sensor connection: G1½ (union nut); Process connection: Socket weld DN32, 40, 50
- For inline measurement at 180°Flow direction
- Max. +90°C / +194°F and 10 bar / 145 psi
SENSOFIT FLOW 1000 Y
Flow-through assembly for chemical and water treatment applications
- For use with Ø12 / 120 mm sensors (pH, ORP, Cl) or conductive conductivity sensors
- Sensor connection: PG13.5, G¾ (female); Process connection: G1 (female)
- For inline measurement at 180°Flow direction
- Max. +95°C / +203°F and 10 bar / 145 psi
SENSOFIT FLOW 2000 C
Flow-through assembly for water and wastewater applications
- For use with optical oxygen and turbidity sensors OPTISENS ODO and TUR 2000 (inline versions)
- Sensor connection: union nut; Process connection: hose connection
- For measurement in small sample streams
- Max. +50°C / +122°F and 6 bar / 87 psi
SENSOFIT FLOW 2000 T
Flow-through assembly for water and wastewater applications
- For use with optical oxygen sensors (OPTISENS ODO 2000)
- Process connection: cemented socket connection 1½”
- For inline measurement at 180° flow direction
- Max. +50C / +122°F and 6 bar / 87 psi
SENSOFIT FLOW 2000 Y
Flow-through assembly for water and wastewater applications
- For use with oxygen sensor OPTISENS ADO 2000
- Sensor connection: Adapter with DN32 union nut; Process connection: DN50 cemented socket connection
- For inline measurement at 180° flow direction
- Max. +50°C / +122°F and 1 bar / 14.5 psi
SENSOFIT IMM 1000
Immersion assembly for general water and wastewater treatment applications
- For use with OPTISENS COND 1200 or ∅12 / 120 mm and ∅0.47 / 4.7″ sensors
- Sensor connection: PG13.5 or G½ (female); Process connection: immersion
- Immersion length: 1 m / 39.37″
- Max. +80°C / +176°F, pressureless
SENSOFIT IMM 2000
Immersion assembly for general water and wastewater treatment applications
- For use with OPTISENS ODO/ADO/TUR 2000, TSS 3000 or sensors with NPT thread
- Sensor connection: ¾ NPT, 1¼ NPT (female); Process connection: Telescopic rod holder mounted to handrail
- Immersion length: flexible, max. 4 m / 13.1 ft
- Max. +60°C / +140°F, pressureless
SENSOFIT IMM 2920
Immersion assembly for chemical and wastewater treatment applications
- For use with Ø12 / 120 mm (Ø0.47 / 4.7″) sensors or sensors with ¾ NPT
- Sensor connection: PG13.5 or ¾ NPT (female); Process connection: Flange DN50 / 2″ or suspended holder
- Immersion length: 1 or 2 m / 39.37″ or 78.74″
- Max. +80°C / +176°F and 4 bar / 58 psi
SENSOFIT INS 7311
Insertion assembly for hygienic applications in the food, beverage and pharmaceutical industry
- For use with Ø12 / 120 mm or Ø0.47 / 4.7″ sensors
- Sensor connection: PG13.5; Process connection: Tri-Clamp 1″, 1½”, 2″
- Insertion length: 45 mm / 1.77″
- Max. +140°C / +284°F and 10 bar / 145 psi
SENSOFIT INS 1310
Insertion assembly for all-purpose applications in various industries
- For use with Ø12 / 120 mm or Ø0.47 / 4.7″ sensors
- Sensor connection: PG13.5; Process connection: INGOLD G1¼ (coupling nut)
- Insertion length: 70 mm / 2.75″
- Max. +140°C / +284°F and 10 bar / 145 psi
SENSOFIT INS 7312
Insertion assembly for hygienic applications in the food, beverage and pharmaceutical industry
- For use with Ø12 / 120 mm or Ø0.47 / 4.7″ sensors
- Sensor connection: PG13.5; Process connection: VARIVENT® N
- Insertion length: 40 or 45 mm / 1.57″ or 1.77″
- Max. +140°C / +284°F and 10 bar / 145 psi
SENSOFIT RET 5000
Manual retractable assembly for harsh chemical and water treatment applications
- For use with Ø12 / 120 mm or Ø0.47 / 4.7″ sensors for high operational safety (exchange, calibration, cleaning without process interruption)
- Sensor connection: PG13.5; Process connection: Flange DN32, 50 / 1¼”, 2″; G1¼ (male); 1¼ NPT (male)
- Insertion length: adjustable, max. 720 mm / 28.3″
- Max. +130°C / +266°F and 12 bar / 174 psi
SENSOFIT RET 5810
Manual retractable assembly for harsh chemical and water treatment applications
- For use with Ø12 / 225 mm or Ø0.47 / 8.9″ sensors; for exchange, calibration and cleaning without process interruption
- Sensor connection: PG13.5; Process connection: Flange DN32, 40, 50 / 2″
- Insertion length: 107 mm / 4.21″
- Max. +140°C / +284°F and 16 bar / 232 psi
SENSOFIT MOUNT 1000
Mounting assembly for applications in various industries
- For use with retractable or insertion assemblies into pipes and tanks
- Assembly connection: G1¼ (male); Process connection: Socket weld
- Straight or inclined version
- Max. +140°C / +284°F and 16 bar / 232 psi
SMARTPAT COND 1200
Conductive conductivity sensor for water and wastewater applications
- 2-wire loop powered, 4…20 mA/HART® 7, for direct connection to a PCS
- Process connection: G¾ (male)
- 0.1…20 mS/cm; Max. +135°C / +275°F; 16 bar / 232 psi
- With stainless steel electrodes and Pt1000 for temperature compensation
SMARTPAT COND 3200
Conductive conductivity sensor for condensate, process, boiler feed or (ultra)pure water
- 2-wire loop powered, 4…20 mA/HART® 7, for direct connection to a PCS
- Process connection: G¾ (male), ¾ NPT (male)
- 0.05…1000 μS/cm; Max. +135°C / +275°F; 16 bar / 232 psi
- With stainless steel electrodes and Pt1000 for temperature compensation
SMARTPAT COND 5200
Conductive conductivity sensor for chemicals and industrial wastewater applications
- 2-wire loop powered, 4…20 mA/HART® 7, for direct connection to a PCS
- Process connection: G¾ (male), ¾ NPT (male)
- 10 μS…15 mS/cm; Max. +130°C / +266°F; 16 bar / 232 psi
- With graphite electrodes and Pt1000 for temperature compensation
SMARTPAT COND 7200
Conductive conductivity sensor for food, beverage and pharmaceutical applications
- 2-wire loop powered, 4…20 mA/HART®7, for direct connection to a PCS
- Process connection: VARIVENT® N, Tri-Clamp 1½”, 2″
- 0.05…1000 μS/cm; Max. +135°C / +275°F; 16 bar / 232 psi
- With stainless steel electrodes (Ra <0.8 μm) and Pt1000 for temperature compensation
OPTISENS COND 1200
Conductive conductivity sensor for water, wastewater, process water or pure water
- For use with analytical transmitter
- Process connection: G½, G¾, G1, ¾ NPT (male)
- 0.05 μS/cm…20 mS/cm; Max. +135°C / +275°F
- With two stainless steel, titanium or graphite electrodes and Pt100 for temperature compensation
OPTISENS COND 7200
Conductive conductivity sensor for hygienic applications
- For use with analytical transmitter
- Process connection: Clamp DN25-40, 1½”
- 0.05…1000 μS/cm; Max. +135°C / +275°F
- Short or long version with stainless steel electrodes and Pt100 for temperature compensation
OPTISENS IND 1000
Inductive conductivity sensor for water, wastewater and chemical applications
- For use with analytical transmitter
- Process connection: G1½ union nut and immersion versions
- 1…2000 mS/cm; Max. +100°C / +212°F
- Electrodeless conductivity sensor with Pt1000 for temperature compensation
OPTISENS IND 7000
Inductive conductivity sensor for food and beverage applications
- For use with analytical transmitter
- Process connection: Dairy screw (DIN 11851) DN50 and DN65, VARIVENT® N, G1½ or G2 (male, non-hygienic)
- 0.5…2000 mS/cm; Max. +125°C / +257°F (for SIP/CIP); 10 bar / 145 psi
- Sterilisable PEEK sensor (FDA and EC1935/2004 conform) with temperature compensation
OPTISYS IND 7100
Inductive conductivity measuring system for food and beverage applications
- 4-wire, 4…20 mA, with head-mounted transmitter
- Process connection: Conical nozzle (DIN 11851) DN50
- 0.5…2000 mS/cm; Max. +120°C / +248°F; 10 bar / 145 psi
- PEEK sensor (FDA and EC1935/2004), with temperature compensation
OPTISYS IND 8100
Inductive conductivity measuring system for food and beverage applications
- 4-wire, 4…20 mA, with head-mounted or remote transmitter
- Process connection: G1 for hygienic adapters
- 0.05…1000 mS/cm; Max. +140°C / +285°F; 10 bar / 145 psi
- Hygienic PEEK sensor, robust (IP69K), with temperature compensation
OPTISENS CL 1100
Potentiostatic amperometric disinfectant sensor for water and wastewater applications
- For use with MAC 100 analytical transmitter
- Process connection: PG13.5
- Cl2: 0.03…20 mg/l; ClO2: 0.05…5 mg/l; O3: 0.05…5 mg/l; Max. +70°C / +158°F; 6 bar / 87 psi
- Membrane-free sensor with 2 gold electrodes and sensor cleaning feature
OPTISYS CL 1100
Potentiostatic amperometric disinfectant measuring system for water and wastewater applications
- Completely mounted with MAC 100 analytical transmitter (Output: 3 x 4…20 mA)
- Pre-installed and tested; for bypass lines
- Cl2: 0.03…20 mg/l; ClO2: 0.05…5 mg/l; O3: 0.05…5 mg/l; Max. +50°C / +122°F; 6 bar / 87 psi
- With chlorine sensor, valves, flow cells, optional pH sensor
Water analysis panel
New
Multi-parameter measuring system for water quality monitoring
- Flexibility in selecting different water parameters: dissolved oxygen, turbidity, conductivity, pH/ORP
- Installation on compact analytical modules: All measuring points at one location
- Completely pre-wired and pre-assembled for easy bypass installation
SMARTPAT ORP 1590
Potentiometric ORP sensor for water and wastewater applications
- 2-wire loop powered, 4…20 mA/HART® 7, for direct connection to a PCS
- Process connection: ¾ NPT (male)
- -1500…+1500 mV; Max. +80°C / +176°F; 6.9 bar / 100 psi
- Sensor with CPVC body, platinum electrode, ceramic diaphragm and Pt1000 temperature sensor
SMARTPAT ORP 8150
Potentiometric ORP sensor for chemicals and industrial wastewater applications
- 2-wire loop powered, 4…20 mA/HART® 7, for direct connection to a PCS
- Process connection: PG13.5
- -1500…+1500 mV; Max. +130°C / +266°F; 12 bar / 174 psi
- Glass sensor with platinum electrode, open diaphragm and Pt1000 temperature sensor
SMARTPAT ORP 8510
Potentiometric ORP sensor for water and wastewater applications
- 2-wire loop powered, 4…20 mA/HART® 7, for direct connection to a PCS
- Process connection: PG13.5
- -1500…+1500 mV; Max. +70°C / +158°F; 2 bar / 30 psi
- Glass sensor with platinum electrode, ceramic diaphragm and Pt1000 temperature sensor