SMARTBASE
Product discontinued
Database for all SMARTPAT PH sensors
- Storage function for configuration and calibration data
- Handling of sensor data during offline calibration and configuration
- With module for statistical analysis of historical data
- With PACTware™ software philosophy
SD 200
Multiparameter indicator for analytical and other parameters
- Loop powered, 4…20 mA, with signal calibration feature (passive), HART® 7
- Indication of multiple units (analytical values, temperature, pressure etc.)
- With LCD display for wall or rack mount
- Power supply: 15…30 VDC (loop powered), 2 V voltage drop
OPTIBRIDGE
USB interface cable for offline calibration and configuration of SMARTPAT sensors
- For direct communication between a 2-wire or passive 4…20 mA HART® device and a PC
- With PACTware™ FDT/DTMs for each parameter
- Different adapter cables available
- No external power supply required
SJB 200
Junction box for connecting SMARTPAT to HART® devices
- Internal connection: Connecting terminals for HART® handhelds
- External connection: M12 connector
- With die-cast aluminium housing (IP66)
- -40…+65°C / -40…+149°F (ambient)
SENSOFIT RAM 5810
Automatic retractable assembly for harsh chemical and water treatment applications
- For use with ∅12 / 225 mm or ∅0.47 / 8.9″ sensors; for exchange, calibration and cleaning without process interruption
- Sensor connection: PG13.5; Process connection: DN32, 40, 50 / 2″
- Insertion length: 107 mm / 4.21″
- Max. +140°C / +284°F and 16 bar / 232 psi
SENSOFIT RAM 5830
Automatic retractable assembly for hygienic applications in the food, beverage and pharmaceutical industry
- For use with ∅12 / 225 mm or ∅0.47 / 8.9″ sensors; for exchange, calibration and cleaning without process interruption
- Sensor connection: PG13.5; Process connection: INGOLD G1¼ (coupling nut)
- Insertion length: 107 mm / 4.21″
- Max. +140°C / +284°F and 16 bar / 232 psi
SENSOFIT FLOW 1000 T
Flow-through assembly for chemical and water treatment applications
- For use with OPTISENS IND 1000 inductive conductivity sensor
- Sensor connection: G1½ (union nut); Process connection: Socket weld DN32, 40, 50
- For inline measurement at 180°Flow direction
- Max. +90°C / +194°F and 10 bar / 145 psi
SENSOFIT FLOW 1000 Y
Flow-through assembly for chemical and water treatment applications
- For use with Ø12 / 120 mm sensors (pH, ORP, Cl) or conductive conductivity sensors
- Sensor connection: PG13.5, G¾ (female); Process connection: G1 (female)
- For inline measurement at 180°Flow direction
- Max. +95°C / +203°F and 10 bar / 145 psi
SENSOFIT FLOW 2000 C
Flow-through assembly for water and wastewater applications
- For use with optical oxygen and turbidity sensors OPTISENS ODO and TUR 2000 (inline versions)
- Sensor connection: union nut; Process connection: hose connection
- For measurement in small sample streams
- Max. +50°C / +122°F and 6 bar / 87 psi
SENSOFIT FLOW 2000 T
Flow-through assembly for water and wastewater applications
- For use with optical oxygen sensors (OPTISENS ODO 2000)
- Process connection: cemented socket connection 1½”
- For inline measurement at 180° flow direction
- Max. +50C / +122°F and 6 bar / 87 psi
SENSOFIT FLOW 2000 Y
Flow-through assembly for water and wastewater applications
- For use with oxygen sensor OPTISENS ADO 2000
- Sensor connection: Adapter with DN32 union nut; Process connection: DN50 cemented socket connection
- For inline measurement at 180° flow direction
- Max. +50°C / +122°F and 1 bar / 14.5 psi
SENSOFIT IMM 1000
Immersion assembly for general water and wastewater treatment applications
- For use with OPTISENS COND 1200 or ∅12 / 120 mm and ∅0.47 / 4.7″ sensors
- Sensor connection: PG13.5 or G½ (female); Process connection: immersion
- Immersion length: 1 m / 39.37″
- Max. +80°C / +176°F, pressureless
SENSOFIT IMM 2000
Immersion assembly for general water and wastewater treatment applications
- For use with OPTISENS ODO/ADO/TUR 2000, TSS 3000 or sensors with NPT thread
- Sensor connection: ¾ NPT, 1¼ NPT (female); Process connection: Telescopic rod holder mounted to handrail
- Immersion length: flexible, max. 4 m / 13.1 ft
- Max. +60°C / +140°F, pressureless
SENSOFIT IMM 2920
Immersion assembly for chemical and wastewater treatment applications
- For use with Ø12 / 120 mm (Ø0.47 / 4.7″) sensors or sensors with ¾ NPT
- Sensor connection: PG13.5 or ¾ NPT (female); Process connection: Flange DN50 / 2″ or suspended holder
- Immersion length: 1 or 2 m / 39.37″ or 78.74″
- Max. +80°C / +176°F and 4 bar / 58 psi
SENSOFIT INS 7311
Insertion assembly for hygienic applications in the food, beverage and pharmaceutical industry
- For use with Ø12 / 120 mm or Ø0.47 / 4.7″ sensors
- Sensor connection: PG13.5; Process connection: Tri-Clamp 1″, 1½”, 2″
- Insertion length: 45 mm / 1.77″
- Max. +140°C / +284°F and 10 bar / 145 psi
SENSOFIT INS 1310
Insertion assembly for all-purpose applications in various industries
- For use with Ø12 / 120 mm or Ø0.47 / 4.7″ sensors
- Sensor connection: PG13.5; Process connection: INGOLD G1¼ (coupling nut)
- Insertion length: 70 mm / 2.75″
- Max. +140°C / +284°F and 10 bar / 145 psi
SENSOFIT INS 7312
Insertion assembly for hygienic applications in the food, beverage and pharmaceutical industry
- For use with Ø12 / 120 mm or Ø0.47 / 4.7″ sensors
- Sensor connection: PG13.5; Process connection: VARIVENT® N
- Insertion length: 40 or 45 mm / 1.57″ or 1.77″
- Max. +140°C / +284°F and 10 bar / 145 psi
SENSOFIT RET 5000
Manual retractable assembly for harsh chemical and water treatment applications
- For use with Ø12 / 120 mm or Ø0.47 / 4.7″ sensors for high operational safety (exchange, calibration, cleaning without process interruption)
- Sensor connection: PG13.5; Process connection: Flange DN32, 50 / 1¼”, 2″; G1¼ (male); 1¼ NPT (male)
- Insertion length: adjustable, max. 720 mm / 28.3″
- Max. +130°C / +266°F and 12 bar / 174 psi
SENSOFIT RET 5810
Manual retractable assembly for harsh chemical and water treatment applications
- For use with Ø12 / 225 mm or Ø0.47 / 8.9″ sensors; for exchange, calibration and cleaning without process interruption
- Sensor connection: PG13.5; Process connection: Flange DN32, 40, 50 / 2″
- Insertion length: 107 mm / 4.21″
- Max. +140°C / +284°F and 16 bar / 232 psi
SENSOFIT MOUNT 1000
Mounting assembly for applications in various industries
- For use with retractable or insertion assemblies into pipes and tanks
- Assembly connection: G1¼ (male); Process connection: Socket weld
- Straight or inclined version
- Max. +140°C / +284°F and 16 bar / 232 psi
SMARTPAT COND 1200
Conductive conductivity sensor for water and wastewater applications
- 2-wire loop powered, 4…20 mA/HART® 7, for direct connection to a PCS
- Process connection: G¾ (male)
- 0.1…20 mS/cm; Max. +135°C / +275°F; 16 bar / 232 psi
- With stainless steel electrodes and Pt1000 for temperature compensation
SMARTPAT COND 3200
Conductive conductivity sensor for condensate, process, boiler feed or (ultra)pure water
- 2-wire loop powered, 4…20 mA/HART® 7, for direct connection to a PCS
- Process connection: G¾ (male), ¾ NPT (male)
- 0.05…1000 μS/cm; Max. +135°C / +275°F; 16 bar / 232 psi
- With stainless steel electrodes and Pt1000 for temperature compensation
SMARTPAT COND 5200
Conductive conductivity sensor for chemicals and industrial wastewater applications
- 2-wire loop powered, 4…20 mA/HART® 7, for direct connection to a PCS
- Process connection: G¾ (male), ¾ NPT (male)
- 10 μS…15 mS/cm; Max. +130°C / +266°F; 16 bar / 232 psi
- With graphite electrodes and Pt1000 for temperature compensation
SMARTPAT COND 7200
Conductive conductivity sensor for food, beverage and pharmaceutical applications
- 2-wire loop powered, 4…20 mA/HART®7, for direct connection to a PCS
- Process connection: VARIVENT® N, Tri-Clamp 1½”, 2″
- 0.05…1000 μS/cm; Max. +135°C / +275°F; 16 bar / 232 psi
- With stainless steel electrodes (Ra <0.8 μm) and Pt1000 for temperature compensation