SU 501
SURGEPROTECT SP-F / 1X2-24DC
SURGEPROTECT SP-F / EX-24DC
BM26A-5000
New
Bypass chamber for TDR guided radar, FMCW radar and displacer level transmitter
- Ideal for difficult process conditions, e.g. turbulence, foam
- Large choice of materials, e.g. 316L, 304L, alloy C276, alloy 625
- Measuring range: up to 5.5 m / 18 ft
- For temperatures up to +400°C / +752°F and 400 barg / 5801 psig (depending on installed level transmitter)
BM26A-1000
BM26A-3000
BM26A-6000
BM26A-7000
New
Magnetic level indicator for extreme operating conditions
- Designed for level and interface measurement of high-temperature and high-pressure liquids; no power supply needed
- Measuring range: 0.3…5.5 m / 1...18 ft (others on request)
- Density: 370…1200 kg/m3 / 23.9…74.91 lb/ft3
- Up to +400°C / +752°F; 400 barg / 5801 psig
BM 26 F2200
Magnetic bypass level indicator with guided radar (TDR) for liquid level applications
- Continuous, redundant measurement using two measurement principles in one device
- Measuring range: 0.3…5.5 / 1…18 ft (longer on request)
- Density: 0.5…3 kg/l / 31…187 lb/ft3
- -50…+300°C / -58…+570°F; -1…100 barg / -14.5…1450 psig
BM 26 A
Product discontinued
Magnetic bypass level indicator for liquid and liquid-liquid interface applications
- Continuous level indication; no power supply needed
- Measuring range: 0.3…5.5 / 1…18 ft (longer on request)
- Density: 0.48…3 kg/l / 30…187.3 lb/ft3
- -196…+300°C / -321…+570°F; -1…100 psig / -14…1450 psig
BM 26 ADVANCED
Product discontinued
Magnetic bypass level indicator with removable float for basic applications with liquids
- Continuous level measurement; no power supply needed
- Measuring range: 0.3…5.3 m / 1…17.4 ft (longer on request)
- Density: 0.58…2 kg/l / 36.2…124.8 lb/ft3
- -40…+300°C / +570°F; -1…40 barg / -14.5…580 psig
BM 26 BASIC
Product discontinued
Magnetic bypass level indicator with non-removable float for basic liquid applications
- Continuous level measurement; no power supply needed
- Measuring range: 0.3…5.3 m / 1…17.4 ft (longer on request)
- Density: 0.8…1.19 kg/l / 49.9…68.7 lb/ft3
- -40…+150°C / +302°F; -1…16 barg / -14.5…232 psig
BM 26 KP
BM 26 PTFE
BM 26 W1010
Product discontinued
Magnetic bypass level indicator with radar (FMCW) for liquid applications
- Continuous redundant measurement using two measurement principles in one device
- Measuring range: 0.3…8 m / 1…26.25 ft (longer on request)
- Density: 0.58…1.2 kg/l / 36…74.9 lb/ft3
- -40…+150°C / +302°F; -1…40 barg / -14.5…580 psig
BM 26 W7300
Product discontinued
Magnetic bypass level indicator with radar (FMCW) for liquid applications
- Continuous, redundant measurement using two measurement principles in one device
- Measuring range: 0.3…5.4 m / 1…17.7 ft (longer on request)
- Density: 0.5…3 kg/l / 31…187 lb/ft3
- -50…+200°C / -58…+392°F; -1…100 barg / -14.5…1450 psig
OPTISWITCH 6500
OPTISWITCH 6600
OPTISWITCH 3100
OPTISWITCH 3200
OPTISWITCH 3300
OPTISWITCH 4000
OPTISWITCH 5300
OPTISWITCH 5100
OPTISWITCH 5150
OPTISWITCH 5200
OPTISWITCH 5250
BW 25
OPTIFLEX 1100
OPTIFLEX 1300
Guided radar (TDR) level transmitter for heavy-duty level and interface applications
- Continuous measurement of level, distance, volume, mass or liquid-liquid interface
- Measuring range: 0.2…35 m / 0.7…115 ft (liquids), 0.2…35 m / 0.7…115 ft (solids)
- -50…+300°C / -58…+572°F; -1…300 barg / -14.5…4350 psig
OPTIFLEX 7200
Guided radar (TDR) level transmitter for advanced liquid applications
- Continuous level and interface measurement in process or storage tanks, reactors and pressure vessels
- Extensive choice of probes for harsh process conditions
- Measuring range: 0.3…60 m / 1…197 ft
- -50…+250°C / -58…+482°F; -1…100 barg / -14.5…1450 psig
OPTIFLEX 2200
OPTIFLEX 8200
Guided radar (TDR) level transmitter for liquids at high temperature and pressure
- Continuous level and interface measurement in boilers, reactors and separators
- With dynamic gas-phase compensation for boiler applications (in preparation)
- Measuring range: 0.6…60 m / 2…197 ft
- -50…+315°C; -58…+599°F; -1…320 barg; -14.5…4641 psig
OPTIFLEX 3200
OPTIFLEX 6200
Guided radar (TDR) level transmitter for solids from granulates to powders
- Continuous level measurement in buffer silos, bulk storage containers or hoppers
- Insensitive to dusty atmosphere and deposit on the probe
- Measuring range: 0.6…40 m / 2…131 ft
- -50…+200°C / -58…+392°F; -1…40 barg / -14.5…580 psig