Electromagnetic flowmeters
OPTIFLUX 1050
Electromagnetic flowmeter for basic applications with conductive liquids
- Cost-effective flow measurement of liquids (≥5 μS/cm) up to +120°C / +248°F
- Extra isolation of electronics for use in high humidity areas
- Wafer-style design: DN10…150 / ⅜…6″, max. PN40 / ASME Cl 300
- 4…20 mA, pulse, frequency, status, HART®, Modbus
OPTIFLUX 1100
Electromagnetic flowmeter for general applications with conductive liquids
- Economical flow measurement of liquids (≥5 μS/cm) with solid content (≤10%)
- -25…+120°C / -13…+248°F
- Wafer-style design: DN10…150 / ⅜…6″, max. PN40 / ASME Cl 300
- 4…20 mA, pulse, frequency, status, HART®
OPTIFLUX 1300
Electromagnetic flowmeter for OEM applications, dosing systems and compact skids
- Economical flow measurement of liquids (≥5 μS/cm) with solid content (≤70%)
- -25…+120°C / -13…+248°F
- Wafer-style design: DN10…150 / ⅜…6″, max. PN40 / ASME Cl 300
- 3 x 4…20 mA, HART®, Modbus, FF, Profibus-PA/DP, PROFINET
OPTIFLUX 2050
Electromagnetic flowmeter for basic water and wastewater applications
- Liner materials resistant to low concentrated chemicals
- With extra isolation of electronics for use in high humidity areas
- Flange: DN25…1200 / 1…48″, max. PN40 / ASME Cl 300
- 4…20 mA, pulse, frequency, status, HART®, Modbus
OPTIFLUX 2100
Electromagnetic flowmeter for all standard water and wastewater applications
- Chemically resistant liner materials
- Compact version up to IP69, remote version IP68
- Flange: DN25…1200 / 1…48″, max. PN40 / ASME Cl 300
- 4…20 mA, pulse, frequency, status, HART®
AF-E 400
Electromagnetic flowmeter for utilities and industrial automation
- Flow measurement of conductive liquids, e.g. coolants, cold/hot water, chemicals, etc.
- Best-in class temperature range, accuracy, pressure drop and flow range
- Ultra-compact design for parallel installation and tight spaces
- 4…20 mA, pulse, frequency, Modbus, IO-Link
OPTIFLUX 2300
Electromagnetic flowmeter for advanced water and wastewater applications
- High accuracy (±0.2%), with CT approvals (OIML R49, MI-001)
- 0D/0D installation according to OIML R49 accuracy class 1
- Flange: DN25…3000 / 1…120″, max. PN40 / ASME Cl 300
- 3 x 4…20 mA, HART®, Modbus, FF, Profibus-PA/DP, PROFINET
TIDALFLUX 2300
Electromagnetic flowmeter for applications with partially filled pipes
- With integrated capacitive level measurement for flow measurement of water and wastewater (≥10% pipe fill level)
- Accurate (±1%) and cost-saving alternative to open channel systems
- Flange: DN200…1600 / 8…64″
- 3 x 4…20 mA, pulse, HART®, Modbus, PROFINET
WATERFLUX 3050
Electromagnetic flowmeter for basic water applications
- Cost-effective measurement of potable, raw and irrigation water
- Extra isolation of electronics for use in high humidity areas
- Flange: DN25…600 / 1…24″, max. PN16 / ASME Cl 150; others on request
- 4…20 mA, pulse, frequency, status, HART®, Modbus
WATERFLUX 3070
Electromagnetic water meter for district metering of potable water and custody transfer (CT) measurement
- Battery- or mains powered, with battery backup option (incl. Modbus)
- Integrated temperature and pressure measurement for leak monitoring
- CT: MI-001, OIML R49 up to DN600 / 24″, no inlet/outlet runs needed
- Burial installation possible (IP68)
WATERFLUX 3100
Electromagnetic flowmeter for standard water applications
- From raw water measurement to drinking water metering in distribution networks
- No inlet/outlet runs needed
- Up to DN600 / 24″, max. PN16 / ASME Cl 150
- 4…20 mA, pulse, frequency, status, HART®
WATERFLUX 3300
Electromagnetic flowmeter for advanced water applications
- High accuracy (±0.2%) for water consumption metering and distribution networks
- No inlet/outlet runs needed
- CT: MI-001, OIML R49 up to DN600 / 24″
- 3 x 4…20 mA, HART®, Modbus, FF, Profibus-PA/DP, PROFINET
POWERFLUX 4030
Electromagnetic flowmeter for nuclear applications
- Designed and tested for industrial nuclear environments
- DN25…1000 / 1…40″; with resistant ETFE or PFA liner materials
- Free of programmable electronic components
- 4…20 mA
OPTIFLUX 4050
Electromagnetic flowmeter for basic applications with abrasive and aggressive liquids
- Chemically resistant liner materials
- With extra isolation of electronics for use in high humidity areas
- Flange: DN2.5…1200 / ⅒…48″, max. PN40 / ASME Cl 1500
- 4…20 mA, pulse, frequency, status, HART®, Modbus
FLEXMAG 4050
Electromagnetic flowmeter for single use biopharmaceutical applications
- With gamma sterilisable disposable flow tube
- One transmitter accommodates two flow tube diameters
- Wetted material compliant with ISO 10993 and USP Class VI
- High accuracy (±1% of MV), wide measuring range, no recalibration
OPTIFLUX 4100
Electromagnetic flowmeter for standard applications with abrasive and aggressive liquids
- Chemically resistant, for liquids (>5 μS/cm) with solid content (≤10%)
- Up to +180°C / +356°F
- Flange: DN2.5…1200 / ⅒…48″, max. PN40 / ASME Cl 1500
- 4…20 mA, pulse, frequency, status, HART®
OPTIFLUX 4300
Electromagnetic flowmeter for advanced process and custody transfer (CT) applications
- High accuracy (±0.2%), certified for custody transfer
- For low conductivity media (>1 μS/cm) and high solid contents (≤70%)
- Flange: DN2.5…3000 / ⅒…120″, max. PN40 / ASME Cl 1500
- 3 x 4…20 mA, HART®,Modbus, FF, Profibus-PA/DP, PROFINET
POWERFLUX 4300
Electromagnetic flowmeter for nuclear applications
- Designed and tested for industrial nuclear environments
- With resistant ETFE or PFA liner materials
- Flange: DN25…1000 / 1…40″
- 3 x 4…20 mA, HART®, Modbus, FF, Profibus-PA/DP, PROFINET
POWERFLUX 5030
Electromagnetic flowmeter for nuclear applications
- Designed and tested for industrial nuclear environments
- With high-tech ceramic tube (DN2.5…100 / 1⁄10…4″) for very aggressive and abrasive fluids
- Free of programmable electronic components
- 4…20 mA
OPTIFLUX 5100
Electromagnetic flowmeter for demanding applications with aggressive and abrasive media
- With chemically resistant ceramic tube for liquids with solid content (≤10%)
- Up to +180°C / +356°F
- Flange: DN2.5…300 / ⅒…12″, max. PN40 / ASME Cl 300; Wafer: max. DN100 / 4″
- 4…20 mA, pulse, frequency, status, HART®
OPTIFLUX 5300
Electromagnetic flowmeter for advanced process and master meter applications
- Highest accuracy (±0.15%), with ceramic tube for aggressive and abrasive liquids (≤70% solid content) up to +180°C / +356°F
- CT: OIML R117, MI-005 etc.
- Flange: DN2.5…300 / 1/10…12″, max. PN40 / ASME Cl 300; Wafer: DN100 / 4″
- 3 x 4…20 mA, HART®, Modbus, FF, Profibus-PA/DP, PROFINET
POWERFLUX 5300
Electromagnetic flowmeter for nuclear applications
- Designed and tested for industrial nuclear environments
- With high-tech ceramic tube for very aggressive and abrasive fluids
- Space-saving wafer design: DN2.5…100 / 1⁄10…4″
- 3 x 4…20 mA, HART®, Modbus, FF, Profibus-PA/DP, PROFINET
BATCHFLUX 5500
Electromagnetic flowmeter for demanding volumetric filling applications for a wide range of container sizes
- High accuracy measurement in process batching as well as cold or hot filling of conductive liquids, e.g. milk, fruit drinks with solid content, detergents etc.
- With ceramic measuring tube and sintered electrodes for applications up to 16 bar / 232 psi
- Flow tube conforms to EC1935/2004, FDA, GB 4806; 3A certified up to DN25 / 1″
- Frequency output integrated
BATCHFLUX 3100
New
Electromagnetic flowmeter for the volumetric filling of common container sizes
- The most compact filling mag meter in the market for filling of conductive liquids, e.g. water, carbonized soft drinks etc.
- Lightweight, economical design with ceramic flow tube for applications up to 8 bar / 116 psi
- The DN15 / ½″ ceramic tube conforms to EC1935/2004, FDA, GB 4806
- Frequency output integrated