OPTIMASS 6400
Coriolis mass flowmeter for advanced process applications
- High accuracy (±0.05% flat), for cryogenic to HT media (-200…+400°C / -328…+752°F); maintains operation over a wide range of gas fractions and complex flow conditions (EGMTM)
- SIL 2/3; CT: OIML R117, R137, MI-005, MI-002; API, AGA; hygienic certifications
- Flange: DN10…300 / ½…12″, max. PN 160 / ASME Cl 1500
- 3 x 4…20 mA, HART®7, Modbus, FF, Profibus-PA/DP, PROFINET, EtherNet/IP™, Bluetooth®
OPTIMASS 2400
Coriolis mass flowmeter for highest capacity bulk measurement
- For gases and liquids up to 4,600 t/h; maintains operation over a wide range of gas fractions and complex flow conditions (EGMTM)
- CT: OIML R117, MI-005, MI-002; API and AGA compliant
- Flange: DN100…400 / 4…16″, max. PN160 / ASME Cl 1500
- 3 x 4…20 mA, HART®7, Modbus, FF, Profibus-PA/DP, PROFINET, EtherNet/IP™, Bluetooth®
OPTIMASS 7400
Coriolis mass flowmeter for advanced process applications
- High accuracy (±0.1%), for viscous, aggressive or shear-sensitive media; maintains operation over a wide range of gas fractions and complex flow conditions (EGMTM)
- CT: OIML R117, MI-005; API; hygienic certifications
- Flange: DN10…100 / ½…4″, max. PN100 / ASME Cl 600; others
- 3 x 4…20 mA, HART®7, Modbus, FF, Profibus-PA/DP, PROFINET, EtherNet/IP™, Bluetooth®
OPTIMASS 1400
Coriolis mass flowmeter for universal applications and process control
- Mass, density and volume flow of gases and liquids; maintains operation over a wide range of gas fractions and complex flow conditions (EGMTM)
- Also certified for hygienic use
- Flange: DN15…100 / ½…4″, max. PN100 / ASME Cl 600; many hygienic fittings
- 3 x 4…20 mA, HART®7, FF, Profibus-PA/DP, Modbus, PROFINET, EtherNet/IP™, Bluetooth®
OPTIMASS 3400
Coriolis mass flowmeter for low flow and dosing applications
- High accuracy (±0.1%) for gases and liquids >0.3 kg/h / 0.01 lb/min; maintains operation over a wide range of gas fractions and complex flow conditions (EGMTM)
- Standard pressure rating up to 300 bar / 4351 psi
- Flange: DN15 / 1/2“; also thread and clamp connections
- 3 x 4…20 mA, HART®7, Modbus, FF, Profibus-PA/DP, PROFINET, EtherNet/IP™, Bluetooth®
OPTIMASS 7010
Coriolis mass flowmeter for advanced applications and process control
- Single straight tube for mass, density and volume flow of viscous, aggressive or shear-sensitive media
- Also certified for hygienic use
- Flange: DN10…100 / ½…4″, max. PN100 / ASME Cl 600; others
- Integrated Modbus; optional EtherNet/IP™ interface
OPTIMASS 3010
Coriolis mass flowmeter for low flow and dosing applications
- Mass, density and volume flow of liquids and gases (>0.3 kg/h / 0.01 lb/min)
- Standard pressure rating up to 300 bar / 4351 psi
- Flange: DN15 / ½”; thread, clamp, etc.
- Integrated Modbus; optional EtherNet/IP™ interface
OPTIMASS 1010
Coriolis mass flowmeter for universal applications and process control
- For mass, density and volume flow of liquids and gases up to +130°C / +266°F
- Also certified for hygienic use
- Flange: DN15…100 / ½…4″, max. PN100 / ASME Cl 600; many hygienic fittings
- Integrated Modbus; optional EtherNet/IP™ interface
OPTIBATCH 4011
Coriolis mass flowmeter for linear and rotating filling machines
- High accuracy batching of conductive and non-conductive liquids
- Meter size: DN8…15 (FDA, EC1935/2004 etc.)
- Many hygienic fittings
- Integrated Modbus
OPTIGAS 4010
Coriolis mass flowmeter for gas dispenser applications
- High accuracy for CNG and LPG up to 70 kg/min / 155 lb/min
- Thread: ¾ NPT (female); up to 350 bar / 5075 psi
- Integrated Modbus, no separate converter
- EtherNet/IP™ interface
OPTIBAR DP 7060with orifice plate
DP flowmeter for volume flow measurement of liquids, gases and steam
- For basic to very demanding aggressive, abrasive or viscous media
- Up to +400°C / +752°F; max. 160 bar / 2320.1 psi (line pressure)
- Flange: DN50…600 / 2…24″
- 2-wire 4…20 mA/HART®, FF, Profibus-PA
OPTIBAR DP 7060with orifice meter run assembly
DP flowmeter for volume flow measurement of liquids, gases and steam
- For small line sizes
- Up to +400°C / +752°F; max. 160 bar / 2320.1 psi; (line pressure)
- Sizes: DN15…100 / ¾…2″
- 2-wire 4…20 mA/HART®, FF, Profibus-PA
OPTIBAR DP 7060with averaging pitot tube
DP flowmeter for volume flow measurement of liquids, gases and steam
- From basic to engineered versions
- Cryogenic to high temperatures possible (-200…+1000°C / -328…1832°F); max. 160 bar / 2320.1 psi (line pressure)
- Line sizes from DN50…2000 / 2…80″ (larger on request)
- 2-wire 4…20 mA/HART®, FF, Profibus-PA
OPTIBAR DP 7060with cone meter
DP flowmeter for volume flow measurement of liquids, gases and steam
- For basic to engineered versions for challenging flow conditions
- -270…+400°C / -454…+752°F possible; max. 160 bar / 2320.1 psi
- Size: optional DN100…3000 / 4…120″
- 2-wire 4…20 mA/HART®, FF, Profibus-PA
OPTIFLUX 1050
Electromagnetic flowmeter for basic applications with conductive liquids
- Cost-effective flow measurement of liquids (≥5 μS/cm) up to +120°C / +248°F
- Extra isolation of electronics for use in high humidity areas
- Wafer-style design: DN10…150 / ⅜…6″, max. PN40 / ASME Cl 300
- 4…20 mA, pulse, frequency, status, HART®, Modbus
OPTIFLUX 1100
Electromagnetic flowmeter for general applications with conductive liquids
- Economical flow measurement of liquids (≥5 μS/cm) with solid content (≤10%)
- -25…+120°C / -13…+248°F
- Wafer-style design: DN10…150 / ⅜…6″, max. PN40 / ASME Cl 300
- 4…20 mA, pulse, frequency, status, HART®
OPTIFLUX 1300
Electromagnetic flowmeter for OEM applications, dosing systems and compact skids
- Economical flow measurement of liquids (≥5 μS/cm) with solid content (≤70%)
- -25…+120°C / -13…+248°F
- Wafer-style design: DN10…150 / ⅜…6″, max. PN40 / ASME Cl 300
- 3 x 4…20 mA, HART®, Modbus, FF, Profibus-PA/DP, PROFINET
OPTIFLUX 2050
Electromagnetic flowmeter for basic water and wastewater applications
- Liner materials resistant to low concentrated chemicals
- With extra isolation of electronics for use in high humidity areas
- Flange: DN25…1200 / 1…48″, max. PN40 / ASME Cl 300
- 4…20 mA, pulse, frequency, status, HART®, Modbus
OPTIFLUX 2100
Electromagnetic flowmeter for all standard water and wastewater applications
- Chemically resistant liner materials
- Compact version up to IP69, remote version IP68
- Flange: DN25…1200 / 1…48″, max. PN40 / ASME Cl 300
- 4…20 mA, pulse, frequency, status, HART®
AF-E 400
Electromagnetic flowmeter for utilities and industrial automation
- Flow measurement of conductive liquids, e.g. coolants, cold/hot water, chemicals, etc.
- Best-in class temperature range, accuracy, pressure drop and flow range
- Ultra-compact design for parallel installation and tight spaces
- 4…20 mA, pulse, frequency, Modbus, IO-Link
OPTIFLUX 2300
Electromagnetic flowmeter for advanced water and wastewater applications
- High accuracy (±0.2%), with CT approvals (OIML R49, MI-001)
- 0D/0D installation according to OIML R49 accuracy class 1
- Flange: DN25…3000 / 1…120″, max. PN40 / ASME Cl 300
- 3 x 4…20 mA, HART®, Modbus, FF, Profibus-PA/DP, PROFINET
TIDALFLUX 2300
Electromagnetic flowmeter for applications with partially filled pipes
- With integrated capacitive level measurement for flow measurement of water and wastewater (≥10% pipe fill level)
- Accurate (±1%) and cost-saving alternative to open channel systems
- Flange: DN200…1600 / 8…64″
- 3 x 4…20 mA, pulse, HART®, Modbus, PROFINET
WATERFLUX 3050
Electromagnetic flowmeter for basic water applications
- Cost-effective measurement of potable, raw and irrigation water
- Extra isolation of electronics for use in high humidity areas
- Flange: DN25…600 / 1…24″, max. PN16 / ASME Cl 150; others on request
- 4…20 mA, pulse, frequency, status, HART®, Modbus
WATERFLUX 3070
Electromagnetic water meter for district metering of potable water and custody transfer (CT) measurement
- Battery- or mains powered, with battery backup option (incl. Modbus)
- Integrated temperature and pressure measurement for leak monitoring
- CT: MI-001, OIML R49 up to DN600 / 24″, no inlet/outlet runs needed
- Burial installation possible (IP68)