
Dräger BG ProAir
The Dräger BG ProAir is a positive-pressure closed-circuit breathing apparatus designed for long-duration operations; it can be used for up to four hours. The positive-pressure circuit prevents hazardous substances from entering the closed breathing system. Exhaled carbon dioxide is removed by a CO₂ absorber, and the air is cooled and enriched with oxygen before inhalation. Oxygen can optionally be dosed to the work rate. The carrying system distributes weight evenly; reflectors and a buddy light system let team members see the wearer and the device status. Cooling options include advanced regeneration material and a simplified ice system. A high-contrast colour display shows cylinder pressure, warnings and Time-To-Whistle; a Bluetooth module connects to gas detectors and a PC connection is used for data and configuration. Telemetry and RFID, PASS (motionless alarm), ADSU (manual alarm) and temperature measurement are integrated. A low-pressure sensor warns when oxygen runs low. The same system components as the PSS BG 4 (FPS 7000 full face mask with communication, test equipment, oxygen booster pump, Drägersorb) can be used. The device is fully machine washable and needs no tools for maintenance.
Description and features
The Dräger BG ProAir is a positive-pressure closed-circuit breathing apparatus designed for long-duration operations; it can be used for up to four hours. The positive-pressure circuit prevents hazardous substances from entering the closed breathing system. Exhaled carbon dioxide is removed by a CO₂ absorber, and the air is cooled and enriched with oxygen before inhalation. Oxygen can optionally be dosed to the work rate. The carrying system distributes weight evenly; reflectors and a buddy light system let team members see the wearer and the device status. Cooling options include advanced regeneration material and a simplified ice system. A high-contrast colour display shows cylinder pressure, warnings and Time-To-Whistle; a Bluetooth module connects to gas detectors and a PC connection is used for data and configuration. Telemetry and RFID, PASS (motionless alarm), ADSU (manual alarm) and temperature measurement are integrated. A low-pressure sensor warns when oxygen runs low. The same system components as the PSS BG 4 (FPS 7000 full face mask with communication, test equipment, oxygen booster pump, Drägersorb) can be used. The device is fully machine washable and needs no tools for maintenance.
Technical data
- BRAND
- Dräger
- MODEL
- Dräger BG ProAir
- WARNING DEVICE
- Low-pressure sensor: warning when there is too little oxygen for safe breathing
- COMPATIBLE WITH
- Dräger FPS 7000




