Request a quote
PointGard 3100
O2Electrochemical4–20 mAHART
PointGard · Stand-alone gas detector

PointGard 3100

O2Electrochemical4–20 mAHART

Dräger PointGard 3100 is a self-contained gas monitor with a display that uses an electrochemical DrägerSensor to watch for oxygen and toxic gases in ambient air. Besides 4–20 mA and HART outputs it provides relays. Its glass-fibre reinforced polyester housing is rated IP66; it operates from -20 °C to 50 °C and carries CE marking.

GASES
O2
SENSOR TECHNOLOGIES
Electrochemical
OUTPUTS
4–20 mA · HART · Relay
Datasheet (PDF) WhatsApp
Description and features

Dräger PointGard 3100 is a self-contained gas monitor with a display that uses an electrochemical DrägerSensor to watch for oxygen and toxic gases in ambient air. Besides 4–20 mA and HART outputs it provides relays. Its glass-fibre reinforced polyester housing is rated IP66; it operates from -20 °C to 50 °C and carries CE marking.

01Oxygen and toxic gas monitoring with an electrochemical DrägerSensor
024–20 mA and HART outputs, relays
03Self-contained gas monitor with display
04Glass-fibre reinforced polyester housing, IP66
0510–30 V DC or 100–240 V AC supply; CE marking
Technical data
BRAND
Dräger
MODEL
PointGard 3100
GASES
O2
SENSOR TECHNOLOGIES
Electrochemical
OUTPUTS
4–20 mA · HART · Relay
DISPLAY
yes
SIL LEVEL
None
IP RATING
IP66
OPERATING TEMPERATURE
-20–50 °C
POWER SUPPLY
10-30 V (DC) / 100-240 V (AC)
HOUSING
Glass fiber reinforced polyester
OTHER APPROVALS
CE marking
DIMENSIONS
25.5x28x12 cm (H × W × D)
WEIGHT
8.6 lb (3.9 kg)
Documents and certificates
Other CE marking