The Dräger X-act 7000 is an opto-electronic analysis system that works with Dräger MicroTubes to selectively measure carcinogenic and toxic substances in the low ppb range. Based on colorimetric chemical sensors, it delivers results directly on site instead of time-consuming and costly laboratory analyses: insert the right MicroTube, start the measurement and read the result. RFID tags on the MicroTubes carry all calibration data valid for their typical one-year life, so complex function tests and manual calibration are not required. The analyser is certified under ATEX/IECEx for Zone 0 and is dust and splash-proof to IP54. After an automatic self-test it is ready for use; it offers 3-button operation, a 2.4-inch colour display and an internal data logger that is read out with the Dräger CC-Vision software. Five standard batteries provide more than ten hours of measuring with the recommended batteries. With the Dräger X-am Pump connected via the coupler, measurements can be made in hard-to-reach places such as tanks, shafts and pipelines up to 45 metres away.

Datasheet (PDF) WhatsApp
Description and features

The Dräger X-act 7000 is an opto-electronic analysis system that works with Dräger MicroTubes to selectively measure carcinogenic and toxic substances in the low ppb range. Based on colorimetric chemical sensors, it delivers results directly on site instead of time-consuming and costly laboratory analyses: insert the right MicroTube, start the measurement and read the result. RFID tags on the MicroTubes carry all calibration data valid for their typical one-year life, so complex function tests and manual calibration are not required. The analyser is certified under ATEX/IECEx for Zone 0 and is dust and splash-proof to IP54. After an automatic self-test it is ready for use; it offers 3-button operation, a 2.4-inch colour display and an internal data logger that is read out with the Dräger CC-Vision software. Five standard batteries provide more than ten hours of measuring with the recommended batteries. With the Dräger X-am Pump connected via the coupler, measurements can be made in hard-to-reach places such as tanks, shafts and pipelines up to 45 metres away.

01Laboratory-quality measurement in the low ppb range
02Selective measurement with Dräger MicroTubes
03Calibration data on RFID-tagged tubes
04ATEX/IECEx Zone 0 certified
05IP54 dust and splash protection
06Internal data logger, read out with CC-Vision
Technical data
BRAND
Dräger
MODEL
Dräger X-act 7000
MEASURING CONDITIONS
air pressure fluctuations have no effect on the measuring instrument (mass flow measurement principle); any temperature or humidity effects are already taken into account in the factory calibration
COMPATIBLE ITEMS
Dräger MicroTubes
EX AREA USE
Yes

Tube list

37 tubes
SubstanceDescriptionMeasuring rangeTube nameOrder codeDatasheet
Acetic Acid—2 – 50 ppmAcetic Acid 2 – 50 ppm8610330PDF
Acetone—25 – 5000 ppmAcetone 25 – 5000 ppm8610470PDF
AlcoholMetanol olarak10 – 5000 ppmAlcohol 10 – 5000 ppm8610380PDF
Ammonia—1 – 100 ppmAmmonia 1 – 100 ppm8610130PDF
Ammonia—100 – 2500 ppmAmmonia 100 – 2500 ppm8610020PDF
BenzeneMeasured together with the Dräger-Tube Booster Basic (3702013)5 – 150 ppbBenzene 5 – 150 ppb8610600PDF
Benzene—0.15 – 10 ppmBenzene 0.15 – 10 ppm8610030PDF
Benzene—10 – 100 ppmBenzene 10 – 100 ppm8610280PDF
1,3-ButadieneMeasured together with the Dräger-Tube Booster Basic (3702013)25 – 500 ppb1,3-Butadiene 25 – 500 ppb8610460PDF
1,3-Butadiene—0.5 – 25 ppm1,3-Butadiene 0.5 – 25 ppm8610300PDF
Carbon Dioxide—200 – 50000 ppmCarbon Dioxide 200 – 50000 ppm8610190PDF
Carbon Monoxide—2 – 1000 ppmCarbon Monoxide 2 – 1000 ppm8610080PDF
Chlorine—50 – 5000 ppbChlorine 50 – 5000 ppb8610010PDF
Ethylene Oxide—25 – 250 ppbEthylene Oxide 25 – 250 ppb8610200PDF
Ethylene Oxide—0.25 – 10 ppmEthylene Oxide 0.25 – 10 ppm8610580PDF
Formaldehyde—5 – 150 ppbFormaldehyde 5 – 150 ppb8610540PDF
Formaldehyde—0.15 – 3 ppmFormaldehyde 0.15 – 3 ppm8610100PDF
Petroleum HydrocarbonsSiklohekzan olarak10 – 3000 ppmPetroleum Hydrocarbons 10 – 3000 ppm8610270PDF
Hydrochloric Acid—0.5 – 25 ppmHydrochloric Acid 0.5 – 25 ppm8610090PDF
Hydrocyanic Acid—0.5 – 50 ppmHydrocyanic Acid 0.5 – 50 ppm8610520PDF
Hydrogen Sulfide—0.1 – 50 ppmHydrogen Sulfide 0.1 – 50 ppm8610050PDF
Hydrogen Sulfide—100 – 2000 ppmHydrogen Sulfide 100 – 2000 ppm8610220PDF
Mercaptan—50 – 6000 ppbMercaptan 50 – 6000 ppb8610360PDF
Mercury—0.005 – 0.25 mg/m³Mercury 0.005 – 0.25 mg/m³8610350PDF
Methylene Chloride—10 – 500 ppmMethylene Chloride 10 – 500 ppm8610510PDF
Methyl Tert-Butyl Ether (MTBE)—2 – 200 ppmMethyl Tert-Butyl Ether (MTBE) 2 – 200 ppm8610530PDF
Nitrogen Dioxide—0.25 – 25 ppmNitrogen Dioxide 0.25 – 25 ppm8610120PDF
Nitrous Fumes—0.25 – 50 ppmNitrous Fumes 0.25 – 50 ppm8610060PDF
Ozone—10 – 1000 ppbOzone 10 – 1000 ppb8610430PDF
Perchloroethylene—1 – 500 ppmPerchloroethylene 1 – 500 ppm8610040PDF
Phosgene—10 – 1000 ppbPhosgene 10 – 1000 ppb8610340PDF
PhosphineMeasured together with the Dräger-Tube Booster Basic (3702013)50 – 5000 ppbPhosphine 50 – 5000 ppb8610400PDF
Sulfur Dioxide—0.05 – 5 ppmSulfur Dioxide 0.05 – 5 ppm8610110PDF
Toluene—10 – 1000 ppmToluene 10 – 1000 ppm8610250PDF
Trichloroethylene—0.25 – 50 ppmTrichloroethylene 0.25 – 50 ppm8610320PDF
Vinyl Chloride—0.1 – 10 ppmVinyl Chloride 0.1 – 10 ppm8610230PDF
Xylene—10 – 1000 ppmXylene 10 – 1000 ppm8610260PDF

Ranges are as given in the manufacturer’s table; where no unit is stated, see the tube datasheet.

Search tubes across all brands →

Documents and certificates
StandardEditionPerformance
EN 61326-1——