Standard Demand Flow Regulator

Demand Flow Regulator is used mainly for docking stations and regulator is set to open only under vacuum of 3-inch water column which gives a flow rate of 0-3 L/Mn. The regulator comes in both standard C10 connection and High-Pressure NPT connection.
SPECIFICATIONS
Inlet Pressure: 
70 bar or 200 bar
Outlet Flow: 
0-3 L/Mn
Inlet Connection: 
C10-5/8” x 18 UNF-M or 1/4“ NPT F for the high Pressure
Outlet Connection: 
Barbed Outlet
Material: 
Brass or Stainless Steel
Warranty: 
1 year

CGA 165 Valve

This valve is light in weight comes with a ON/OFF knob and a brass CGA 165 outlet connection where a free nut is fitted for coupling.
SPECIFICATIONS
Inlet Pressure: 
35 bar
Inlet Connection: 
1”x14 UNS
Outlet Connection: 
CGA 165
Material: 
Aluminium
Warranty: 
1 year

Mini Flow C10 Valve

It is used with the 20 litre mini gas cylinder. Designed with a simple on/off valve the gas flow is regulated through a Rotameter.
SPECIFICATIONS
Inlet Pressure: 
35 bar
Outlet Flow: 
0 to 1 L/Mn
Inlet Connection: 
C10-5/8” x 18 UNF-M or CGA 600 or Aerosol
Outlet Connection: 
Barbed Outlet
Material: 
Brass
Warranty: 
1 year

Trigger Fixed Flow Regulator

The trigger regulator is designed to provide aerosol capability, this regulator can be used with 34L and 58L aluminium cylinders. The trigger can be used for dispensing gas at flow rate of 0.5L/Mn. And can be flipped upwards into on position for continuous flow of gas.
SPECIFICATIONS
Inlet Pressure: 
70 bar
Outlet Flow: 
0.5 L/Mn
Inlet Connection: 
C10-5/8” x 18 UNF-M
Outlet Connection: 
6mm Straight tube
Material: 
Brass
Warranty: 
1 year

CGA 600 Adapter

The CGA 600 Adapter is used on non-reactive gas cylinders for connecting Fixed Flow regulators, Demand Flow Regulators, Trigger Regulators, Push button Regulators and Multi Flow Regulators. Adapts the any Litre-bottle male thread connection (CGA600) to the any litre-bottle/regulator female thread connection (C10).
SPECIFICATIONS
Inlet Pressure: 
90 bar max
Inlet Connection: 
C10-5/8” x 18 UNF-M
Outlet Connection: 
1”/20 UNEF-F
Material: 
Brass or Stainless Steel
Warranty: 
1 Year

Multi Flow Regulator

Multi Flow regulator is a single stage piston style regulator. The regulator has 9 selectable flow settings. Used with corrosive and non-corrosive gases.
SPECIFICATIONS
Inlet Pressure: 
70 bar or 200 bar
Outlet Flow: 
0 to 3 L/Mn, 0 to 5 L/Mn, 0 to 8 L/Mn, 0 to 15 L/Mn
Inlet Connection: 
C10-5/8” x 18 UNF-M or 1/4“ NPT F for the high Pressure
Outlet Connection: 
Barbed or Compression fitting
Material: 
Brass or Stainless Steel
Warranty: 
1 year

CGA 600 Valve

The Standard CGA 600 valve is used for 17 Litres and 34 Litres steel cylinders.
SPECIFICATIONS
Inlet Pressure: 
35 bar
Inlet Connection: 
1/14” UNS
Outlet Connection: 
1”x20 UNEF-M
Material: 
Stainless Steel
Warranty: 
1 year

NPT Adapter

Choice of 303 stainless steel or nickel-plated brass for adapter body. Rated for pressures up to 90 bar max.
SPECIFICATIONS
Inlet Pressure: 
90 bar max
Inlet Connection: 
¼” NPT-M
Outlet Connection: 
C10-5/8” x 18 TPI UNF-M
Material: 
Brass or Stainless Steel
Warranty: 
1 year

Combination Regulator

Combination Regulator is compatible with standard C10 connection refillable cylinders. The unique design of this regulator allows it to act like a valve and regulator when needed. It consists of ON/OFF knob with pressure gauge to determine the cylinder volume and a gas refiling port on top on of the regulator.
SPECIFICATIONS
Inlet Pressure: 
100 bar
Outlet Flow: 
0.1 to 7 L/Mn
Inlet Connection: 
1/14” UNS
Outlet Connection: 
Barbed Outlet
Material: 
Aluminium
Warranty: 
1 year

Pump Flow Valve

An economical alternative to the standard Demand flow regulator. This is to be used with instruments having built in Vacuum pump.
SPECIFICATIONS
Inlet Pressure: 
70 bar
Outlet Flow: 
0 to 3 L/Mn
Inlet Connection: 
C10-5/8” x 18 UNF-M
Outlet Connection: 
Barbed Outlet
Material: 
Brass
Warranty: 
1 year

Duo Fixed Flow Regulator

The Duo flow regulator is designed to have a button on top for temporary release of gas if the button is pressed down to prevent accidental loss of gas and a rotating cap for situations where continuous flow of gas is required and the regulator is needed to be in on position.   Both mechanisms are easy to use for outlet flow rates of 0.5 L/Mn and 1.0 L/Mn
SPECIFICATIONS
Inlet Pressure: 
70 bar
Outlet Flow: 
0.5 L/Mn & 1.0 L/Mn
Inlet Connection: 
C10-5/8” x 18 UNF-M
Outlet Connection: 
Barbed connection & Taper Shank adaptable to Polyurethane tube.
Material: 
Brass
Warranty: 
1 year

Push Button Fixed Flow Regulator

Push Button Regulator comes with a ON/OFF button on its top as preventive measure for accidental loss of gas and is mainly used for Bump Testing.
SPECIFICATIONS
Inlet Pressure: 
70 bar
Outlet Flow: 
0.5 L/Mn & 1.0 L/Mn
Inlet Connection: 
C10-5/8” x 18 UNF-M
Outlet Connection: 
Taper Shank Adaptable to Polyurethane Tube
Material: 
Brass & Stainless Steel
Warranty: 
1 year