Showing 1–12 of 113 results

OPTITEMP TRA-V40

Resistance (RTD) compact sensor for surface temperature measurement in HVAC applications

  • Hose clamp connection
  • Aluminium junction box with built-in transmitter
  • -25…+80°C / -13…+176°F

OPTITEMP TCA-TS32

Thermocouple (TC) temperature assembly for higher flow velocities and pressures

  • Thread connection
  • DIN-style based on form 5, welded multipart thermowell with straight tip
  • -40…+600°C / +1100°F

OPTITEMP TRA-P40

Resistance (RTD) temperature assembly for standard applications

  • Compression fitting connection
  • DIN-style based on form 3, welded multipart thermowell with tapered tip
  • -40…+600°C / +1100°F

OPTITEMP TT 53 R

Rail-mounted temperature transmitter with universal input, galvanic isolation, HART® and wireless communication

  • Input: RTD, TC, mV, Ω
  • Output: 2-wire, 4…20 mA/HART®7
  • Programmable via PC, HART® handheld or the OPTICHECK Temperature Mobile app using Bluetooth® or NFC
  • Accuracy: ±0.08%

OPTITEMP TRA-W90

Resistance (RTD) cable sensor for extended ambient temperature operation

  • Compression fitting connection
  • Mineral insulated cable and stainless steel sheath, IP68 rated
  • -20…+600°C / -4…+1100°F

OPTITEMP TCA-F42

Thermocouple (TC) temperature assembly for standard applications

  • Flange connection
  • DIN-style based on form 3F, welded multipart thermowell with tapered tip
  • -40…+600°C / +1100°F

OPTITEMP TRA-F13

Resistance (RTD) temperature assembly for standard applications

  • Flange connection
  • DIN-style based on form 2F, welded multipart thermowell with straight tip
  • -40…+600°C / +1100°F

OPTITEMP TT 12 C

New

Head-mounted temperature transmitter with RTD input and extremely compact design

  • Input: 1 x Pt100, 1 x Pt1000, 2-, 3- or 4-wire
  • Output: 2-wire, 4…20 mA
  • Programmable via the OPTICHECK Temperature Mobile app using NFC
  • Accuracy: ±0.15%

OPTITEMP TCA-S22

Thermocouple (TC) temperature assembly for standard applications

  • Thread connection
  • DIN-style based on form 2G, welded multipart thermowell with reduced tip
  • -40…+600°C / +1100°F

OPTITEMP TRA-TF57

Resistance (RTD) temperature assembly for higher flow velocities and pressures

  • Flange connection
  • ASME-style, barstock thermowell with reduced tip
  • -40…+600°C / +1100°F

OPTITEMP TT 11 R

Rail-mounted temperature transmitter with RTD input

  • Input: 1 x Pt100 or 1 Pt1000, 3-wire
  • Output: 3-wire, 0…10 VDC
  • Manually configurable
  • Accuracy: ±0.15%

OPTITEMP TRA-V20

Resistance (RTD) compact sensor for measuring outdoor air temperature in HVAC applications

  • Outdoor sensor for wall-mount installation
  • Aluminium junction box with built-in transmitter
  • -50…+100°C / -58…+212°F