SMARTPAT COND 1200
Process analytics, Analytical sensors and measuring systems, Conductivity sensors and measuring systems
SMARTPAT COND 3200
Process analytics, Analytical sensors and measuring systems, Conductivity sensors and measuring systems
Conductive conductivity sensor for condensate, process, boiler feed or (ultra)pure water
- 2-wire loop powered, 4…20 mA/HART® 7, for direct connection to a PCS
- Process connection: G¾ (male), ¾ NPT (male)
- 0.05…1000 μS/cm; Max. +135°C / +275°F; 16 bar / 232 psi
- With stainless steel electrodes and Pt1000 for temperature compensation
SMARTPAT COND 5200
Process analytics, Analytical sensors and measuring systems, Conductivity sensors and measuring systems
Conductive conductivity sensor for chemicals and industrial wastewater applications
- 2-wire loop powered, 4…20 mA/HART® 7, for direct connection to a PCS
- Process connection: G¾ (male), ¾ NPT (male)
- 10 μS…15 mS/cm; Max. +130°C / +266°F; 16 bar / 232 psi
- With graphite electrodes and Pt1000 for temperature compensation
SMARTPAT COND 7200
Process analytics, Analytical sensors and measuring systems, Conductivity sensors and measuring systems
Conductive conductivity sensor for food, beverage and pharmaceutical applications
- 2-wire loop powered, 4…20 mA/HART®7, for direct connection to a PCS
- Process connection: VARIVENT® N, Tri-Clamp 1½", 2"
- 0.05…1000 μS/cm; Max. +135°C / +275°F; 16 bar / 232 psi
- With stainless steel electrodes (Ra <0.8 μm) and Pt1000 for temperature compensation
OPTISENS COND 1200
Process analytics, Analytical sensors and measuring systems, Conductivity sensors and measuring systems
OPTISENS COND 7200
Process analytics, Analytical sensors and measuring systems, Conductivity sensors and measuring systems
OPTISENS IND 1000
Process analytics, Analytical sensors and measuring systems, Conductivity sensors and measuring systems
OPTISENS IND 7000
Process analytics, Analytical sensors and measuring systems, Conductivity sensors and measuring systems
Inductive conductivity sensor for food and beverage applications
- For use with analytical transmitter
- Process connection: Dairy screw (DIN 11851) DN50 and DN65, VARIVENT® N, G1½ or G2 (male, non-hygienic)
- 0.5…2000 mS/cm; Max. +125°C / +257°F (for SIP/CIP); 10 bar / 145 psi
- Sterilisable PEEK sensor (FDA and EC1935/2004 conform) with temperature compensation
OPTISYS IND 7100
Process analytics, Analytical sensors and measuring systems, Conductivity sensors and measuring systems
OPTISYS IND 8100
Process analytics, Analytical sensors and measuring systems, Conductivity sensors and measuring systems
OPTISENS CL 1100
Process analytics, Analytical sensors and measuring systems, Disinfectant sensors and measuring systems
Potentiostatic amperometric disinfectant sensor for water and wastewater applications
- For use with MAC 100 analytical transmitter
- Process connection: PG13.5
- Cl2: 0.03…20 mg/l; ClO2: 0.05…5 mg/l; O3: 0.05…5 mg/l; Max. +70°C / +158°F; 6 bar / 87 psi
- Membrane-free sensor with 2 gold electrodes and sensor cleaning feature
OPTISYS CL 1100
Process analytics, Analytical sensors and measuring systems, Disinfectant sensors and measuring systems
Potentiostatic amperometric disinfectant measuring system for water and wastewater applications
- Completely mounted with MAC 100 analytical transmitter (Output: 3 x 4…20 mA)
- Pre-installed and tested; for bypass lines
- Cl2: 0.03…20 mg/l; ClO2: 0.05…5 mg/l; O3: 0.05…5 mg/l; Max. +50°C / +122°F; 6 bar / 87 psi
- With chlorine sensor, valves, flow cells, optional pH sensor
Water analysis panel
New
Multi-parameter measuring system for water quality monitoring
- Flexibility in selecting different water parameters: dissolved oxygen, turbidity, conductivity, pH/ORP
- Installation on compact analytical modules: All measuring points at one location
- Completely pre-wired and pre-assembled for easy bypass installation
SMARTPAT ORP 1590
Potentiometric ORP sensor for water and wastewater applications
- 2-wire loop powered, 4…20 mA/HART® 7, for direct connection to a PCS
- Process connection: ¾ NPT (male)
- -1500…+1500 mV; Max. +80°C / +176°F; 6.9 bar / 100 psi
- Sensor with CPVC body, platinum electrode, ceramic diaphragm and Pt1000 temperature sensor
SMARTPAT ORP 8150
Potentiometric ORP sensor for chemicals and industrial wastewater applications
- 2-wire loop powered, 4…20 mA/HART® 7, for direct connection to a PCS
- Process connection: PG13.5
- -1500…+1500 mV; Max. +130°C / +266°F; 12 bar / 174 psi
- Glass sensor with platinum electrode, open diaphragm and Pt1000 temperature sensor
SMARTPAT ORP 8510
OPTISENS ORP 8500
OPTISENS ORP 8590
OPTISENS ADO 2000
OPTISENS ODO 2000
SMARTPAT PH 1590
Potentiometric pH sensor for potable, process or treated water applications
- 2-wire loop powered, 4…20 mA/HART® 7, for direct connection to a PCS
- Process connection: ¾ NPT (male)
- 0…14 pH; Max. +80°C / +176°F; 6.9 bar / 100 psi
- With CPVC sensor body, ceramic diaphragm and Pt1000 for temperature compensation
SMARTPAT PH 8150
SMARTPAT PH 8320
SMARTPAT PH 8530
SMARTPAT PH 8570
Potentiometric pH sensor for food, beverage and pharmaceutical applications
- 2-wire loop powered, 4…20 mA/HART® 7, for direct connection to a PCS
- Process connection: PG13.5
- 0…14 pH; Max. +140°C / +284°F (SIP/CIP); 12 bar / 174 psi
- Autoclavable glass sensor with ceramic diaphragm and Pt1000 for temperature compensation
OPTISENS PH 8100
OPTISENS PH 8300
OPTISENS PH 8390
OPTISENS PH 8500
OPTISENS PH 8590
OPTISENS PH 9100
OPTISENS PH 9500
SMARTPAT PH 2390
Potentiometric pH sensor for municipal and industrial wastewater applications
- 2-wire loop powered, 4…20 mA/HART® 7, for direct connection to a PCS
- Process connection: ¾ NPT (male)
- 0…14 pH; Max. +80°C / +176°F; 6.9 bar / 100 psi
- With PPS sensor body, PTFE diaphragm and Pt1000 for temperature compensation
OPTISYS SLM 2100
Optical sludge level measuring system for sedimentation profile measurement and continuous tracking of sludge blanket
- Integrated electronics with 2 x 4…20 mA, 3 relays, limit switches
- 3 measurement modes: profile, sludge blanket/ fluff levels, zone tracking; automatic change of modes possible
- 0.1…30 g/l; max. 10 m / 32.8 ft
- Optional automatic flush cleaning unit for low maintenance
OPTISENS TSS 2000
Process analytics, Analytical sensors and measuring systems, Total suspended solids sensors and measuring systems
Optical total suspended solids sensor for wastewater applications
- For use with MAC 100 analytical transmitter
- For immersion
- 0…4 AU, 0…18.5 g/l (sludge); max. +70°C / +158°F; 1 bar / 14 psi
- Robust stainless steel sensor using single beam (180° NIR LED) principle, with optical sapphire glass windows
OPTISENS TSS 3000
Process analytics, Analytical sensors and measuring systems, Total suspended solids sensors and measuring systems
Optical total suspended solids sensor for wastewater applications
- For use with MAC 300 analytical transmitter
- Process connection: 1¼ NPT (male)
- 0…2.5, 10 or 25 g/l (sludge); Max. +85°C / +185°F; 10 bar / 145 psi
- PP sensor using 4-beam alternating light principle, no optical windows, glass free