Showing 1–24 of 67 results

SMARTBASE

Product discontinued

Database for all SMARTPAT PH sensors

  • Storage function for configuration and calibration data
  • Handling of sensor data during offline calibration and configuration
  • With module for statistical analysis of historical data
  • With PACTware™ software philosophy

SD 200

Multiparameter indicator for analytical and other parameters

  • Loop powered, 4…20 mA, with signal calibration feature (passive), HART® 7
  • Indication of multiple units (analytical values, temperature, pressure etc.)
  • With LCD display for wall or rack mount
  • Power supply: 15…30 VDC (loop powered), 2 V voltage drop

OPTIBRIDGE

USB interface cable for offline calibration and configuration of SMARTPAT sensors

  • For direct communication between a 2-wire or passive 4…20 mA HART® device and a PC
  • With PACTware™ FDT/DTMs for each parameter
  • Different adapter cables available
  • No external power supply required

SJB 200

Junction box for connecting SMARTPAT to HART® devices

  • Internal connection: Connecting terminals for HART® handhelds
  • External connection: M12 connector
  • With die-cast aluminium housing (IP66)
  • -40…+65°C / -40…+149°F (ambient)

SENSOFIT RAM 5810

Automatic retractable assembly for harsh chemical and water treatment applications

  • For use with ∅12 / 225 mm or ∅0.47 / 8.9" sensors; for exchange, calibration and cleaning without process interruption
  • Sensor connection: PG13.5; Process connection: DN32, 40, 50 / 2"
  • Insertion length: 107 mm / 4.21"
  • Max. +140°C / +284°F and 16 bar / 232 psi

SENSOFIT RAM 5830

Automatic retractable assembly for hygienic applications in the food, beverage and pharmaceutical industry

  • For use with ∅12 / 225 mm or ∅0.47 / 8.9" sensors; for exchange, calibration and cleaning without process interruption
  • Sensor connection: PG13.5; Process connection: INGOLD G1¼ (coupling nut)
  • Insertion length: 107 mm / 4.21"
  • Max. +140°C / +284°F and 16 bar / 232 psi

SENSOFIT FLOW 1000 T

Flow-through assembly for chemical and water treatment applications

  • For use with OPTISENS IND 1000 inductive conductivity sensor
  • Sensor connection: G1½ (union nut); Process connection: Socket weld DN32, 40, 50
  • For inline measurement at 180°Flow direction
  • Max. +90°C / +194°F and 10 bar / 145 psi

SENSOFIT FLOW 1000 Y

Flow-through assembly for chemical and water treatment applications

  • For use with Ø12 / 120 mm sensors (pH, ORP, Cl) or conductive conductivity sensors
  • Sensor connection: PG13.5, G¾ (female); Process connection: G1 (female)
  • For inline measurement at 180°Flow direction
  • Max. +95°C / +203°F and 10 bar / 145 psi

SENSOFIT FLOW 2000 C

Flow-through assembly for water and wastewater applications

  • For use with optical oxygen and turbidity sensors OPTISENS ODO and TUR 2000 (inline versions)
  • Sensor connection: union nut; Process connection: hose connection
  • For measurement in small sample streams
  • Max. +50°C / +122°F and 6 bar / 87 psi

SENSOFIT FLOW 2000 T

Flow-through assembly for water and wastewater applications

  • For use with optical oxygen sensors (OPTISENS ODO 2000)
  • Process connection: cemented socket connection 1½"
  • For inline measurement at 180° flow direction
  • Max. +50C / +122°F and 6 bar / 87 psi

SENSOFIT FLOW 2000 Y

Flow-through assembly for water and wastewater applications

  • For use with oxygen sensor OPTISENS ADO 2000
  • Sensor connection: Adapter with DN32 union nut; Process connection: DN50 cemented socket connection
  • For inline measurement at 180° flow direction
  • Max. +50°C / +122°F and 1 bar / 14.5 psi

    SENSOFIT IMM 1000

    Immersion assembly for general water and wastewater treatment applications

    • For use with OPTISENS COND 1200 or ∅12 / 120 mm and ∅0.47 / 4.7" sensors
    • Sensor connection: PG13.5 or G½ (female); Process connection: immersion
    • Immersion length: 1 m / 39.37"
    • Max. +80°C / +176°F, pressureless

    SENSOFIT IMM 2000

    Immersion assembly for general water and wastewater treatment applications

    • For use with OPTISENS ODO/ADO/TUR 2000, TSS 3000 or sensors with NPT thread
    • Sensor connection: ¾ NPT, 1¼ NPT (female); Process connection: Telescopic rod holder mounted to handrail
    • Immersion length: flexible, max. 4 m / 13.1 ft
    • Max. +60°C / +140°F, pressureless

    SENSOFIT IMM 2920

    Immersion assembly for chemical and wastewater treatment applications

    • For use with Ø12 / 120 mm (Ø0.47 / 4.7") sensors or sensors with ¾ NPT
    • Sensor connection: PG13.5 or ¾ NPT (female); Process connection: Flange DN50 / 2" or suspended holder
    • Immersion length: 1 or 2 m / 39.37" or 78.74"
    • Max. +80°C / +176°F and 4 bar / 58 psi

    SENSOFIT INS 7311

    Insertion assembly for hygienic applications in the food, beverage and pharmaceutical industry

    • For use with Ø12 / 120 mm or Ø0.47 / 4.7" sensors
    • Sensor connection: PG13.5; Process connection: Tri-Clamp 1", 1½", 2"
    • Insertion length: 45 mm / 1.77"
    • Max. +140°C / +284°F and 10 bar / 145 psi

    SENSOFIT INS 1310

    Insertion assembly for all-purpose applications in various industries

    • For use with Ø12 / 120 mm or Ø0.47 / 4.7" sensors
    • Sensor connection: PG13.5; Process connection: INGOLD G1¼ (coupling nut)
    • Insertion length: 70 mm / 2.75"
    • Max. +140°C / +284°F and 10 bar / 145 psi

    SENSOFIT INS 7312

    Insertion assembly for hygienic applications in the food, beverage and pharmaceutical industry

    • For use with Ø12 / 120 mm or Ø0.47 / 4.7" sensors
    • Sensor connection: PG13.5; Process connection: VARIVENT® N
    • Insertion length: 40 or 45 mm / 1.57" or 1.77"
    • Max. +140°C / +284°F and 10 bar / 145 psi

    SENSOFIT RET 5000

    Manual retractable assembly for harsh chemical and water treatment applications

    • For use with Ø12 / 120 mm or Ø0.47 / 4.7" sensors for high operational safety (exchange, calibration, cleaning without process interruption)
    • Sensor connection: PG13.5; Process connection: Flange DN32, 50 / 1¼", 2"; G1¼ (male); 1¼ NPT (male)
    • Insertion length: adjustable, max. 720 mm / 28.3"
    • Max. +130°C / +266°F and 12 bar / 174 psi

    SENSOFIT RET 5810

    Manual retractable assembly for harsh chemical and water treatment applications

    • For use with Ø12 / 225 mm or Ø0.47 / 8.9" sensors; for exchange, calibration and cleaning without process interruption
    • Sensor connection: PG13.5; Process connection: Flange DN32, 40, 50 / 2"
    • Insertion length: 107 mm / 4.21"
    • Max. +140°C / +284°F and 16 bar / 232 psi

    SENSOFIT MOUNT 1000

    Mounting assembly for applications in various industries

    • For use with retractable or insertion assemblies into pipes and tanks
    • Assembly connection: G1¼ (male); Process connection: Socket weld
    • Straight or inclined version
    • Max. +140°C / +284°F and 16 bar / 232 psi

    SMARTPAT COND 1200

    Conductive conductivity sensor for water and wastewater applications

    • 2-wire loop powered, 4…20 mA/HART® 7, for direct connection to a PCS
    • Process connection: G¾ (male)
    • 0.1…20 mS/cm; Max. +135°C / +275°F; 16 bar / 232 psi
    • With stainless steel electrodes and Pt1000 for temperature compensation

    SMARTPAT COND 3200

    Conductive conductivity sensor for condensate, process, boiler feed or (ultra)pure water

    • 2-wire loop powered, 4…20 mA/HART® 7, for direct connection to a PCS
    • Process connection: G¾ (male), ¾ NPT (male)
    • 0.05…1000 μS/cm; Max. +135°C / +275°F; 16 bar / 232 psi
    • With stainless steel electrodes and Pt1000 for temperature compensation

    SMARTPAT COND 5200

    Conductive conductivity sensor for chemicals and industrial wastewater applications

    • 2-wire loop powered, 4…20 mA/HART® 7, for direct connection to a PCS
    • Process connection: G¾ (male), ¾ NPT (male)
    • 10 μS…15 mS/cm; Max. +130°C / +266°F; 16 bar / 232 psi
    • With graphite electrodes and Pt1000 for temperature compensation

    SMARTPAT COND 7200

    Conductive conductivity sensor for food, beverage and pharmaceutical applications

    • 2-wire loop powered, 4…20 mA/HART®7, for direct connection to a PCS
    • Process connection: VARIVENT® N, Tri-Clamp 1½", 2"
    • 0.05…1000 μS/cm; Max. +135°C / +275°F; 16 bar / 232 psi
    • With stainless steel electrodes (Ra <0.8 μm) and Pt1000 for temperature compensation