Showing 1–24 of 30 results

OPTIFLUX 1050

Electromagnetic flowmeter for basic applications with conductive liquids

  • Cost-effective flow measurement of liquids (≥5 μS/cm) up to +120°C / +248°F
  • Extra isolation of electronics for use in high humidity areas
  • Wafer-style design: DN10…150 / ⅜…6", max. PN40 / ASME Cl 300
  • 4…20 mA, pulse, frequency, status, HART®, Modbus

OPTIFLUX 1100

Electromagnetic flowmeter for general applications with conductive liquids

  • Economical flow measurement of liquids (≥5 μS/cm) with solid content (≤10%)
  • -25…+120°C / -13…+248°F
  • Wafer-style design: DN10…150 / ⅜…6", max. PN40 / ASME Cl 300
  • 4…20 mA, pulse, frequency, status, HART®

OPTIFLUX 1300

Electromagnetic flowmeter for OEM applications, dosing systems and compact skids

  • Economical flow measurement of liquids (≥5 μS/cm) with solid content (≤70%)
  • -25…+120°C / -13…+248°F
  • Wafer-style design: DN10…150 / ⅜…6", max. PN40 / ASME Cl 300
  • 3 x 4…20 mA, HART®, Modbus, FF, Profibus-PA/DP, PROFINET

OPTIFLUX 2050

Electromagnetic flowmeter for basic water and wastewater applications

  • Liner materials resistant to low concentrated chemicals
  • With extra isolation of electronics for use in high humidity areas
  • Flange: DN25…1200 / 1…48", max. PN40 / ASME Cl 300
  • 4…20 mA, pulse, frequency, status, HART®, Modbus

OPTIFLUX 2100

Electromagnetic flowmeter for all standard water and wastewater applications

  • Chemically resistant liner materials
  • Compact version up to IP69, remote version IP68
  • Flange: DN25…1200 / 1…48", max. PN40 / ASME Cl 300
  • 4…20 mA, pulse, frequency, status, HART®

AF-E 400

Electromagnetic flowmeter for utilities and industrial automation

  • Flow measurement of conductive liquids, e.g. coolants, cold/hot water, chemicals, etc.
  • Best-in class temperature range, accuracy, pressure drop and flow range
  • Ultra-compact design for parallel installation and tight spaces
  • 4…20 mA, pulse, frequency, Modbus, IO-Link

OPTIFLUX 2300

Electromagnetic flowmeter for advanced water and wastewater applications

  • High accuracy (±0.2%), with CT approvals (OIML R49, MI-001)
  • 0D/0D installation according to OIML R49 accuracy class 1
  • Flange: DN25…3000 / 1…120", max. PN40 / ASME Cl 300
  • 3 x 4…20 mA, HART®, Modbus, FF, Profibus-PA/DP, PROFINET

TIDALFLUX 2300

Electromagnetic flowmeter for applications with partially filled pipes

  • With integrated capacitive level measurement for flow measurement of water and wastewater (≥10% pipe fill level)
  • Accurate (±1%) and cost-saving alternative to open channel systems
  • Flange: DN200…1600 / 8…64"
  • 3 x 4…20 mA, pulse, HART®, Modbus, PROFINET

WATERFLUX 3050

Electromagnetic flowmeter for basic water applications

  • Cost-effective measurement of potable, raw and irrigation water
  • Extra isolation of electronics for use in high humidity areas
  • Flange: DN25…600 / 1…24", max. PN16 / ASME Cl 150; others on request
  • 4…20 mA, pulse, frequency, status, HART®, Modbus

WATERFLUX 3070

Electromagnetic water meter for district metering of potable water and custody transfer (CT) measurement

  • Battery- or mains powered, with battery backup option (incl. Modbus)
  • Integrated temperature and pressure measurement for leak monitoring
  • CT: MI-001, OIML R49 up to DN600 / 24", no inlet/outlet runs needed
  • Burial installation possible (IP68)

WATERFLUX 3100

Electromagnetic flowmeter for standard water applications

  • From raw water measurement to drinking water metering in distribution networks
  • No inlet/outlet runs needed
  • Up to DN600 / 24", max. PN16 / ASME Cl 150
  • 4…20 mA, pulse, frequency, status, HART®

WATERFLUX 3300

Electromagnetic flowmeter for advanced water applications

  • High accuracy (±0.2%) for water consumption metering and distribution networks
  • No inlet/outlet runs needed
  • CT: MI-001, OIML R49 up to DN600 / 24"
  • 3 x 4…20 mA, HART®, Modbus, FF, Profibus-PA/DP, PROFINET

POWERFLUX 4030

Electromagnetic flowmeter for nuclear applications

  • Designed and tested for industrial nuclear environments
  • DN25…1000 / 1…40"; with resistant ETFE or PFA liner materials
  • Free of programmable electronic components
  • 4…20 mA

OPTIFLUX 4050

Electromagnetic flowmeter for basic applications with abrasive and aggressive liquids

  • Chemically resistant liner materials
  • With extra isolation of electronics for use in high humidity areas
  • Flange: DN2.5…1200 / ⅒…48", max. PN40 / ASME Cl 1500
  • 4…20 mA, pulse, frequency, status, HART®, Modbus

FLEXMAG 4050

Electromagnetic flowmeter for single use biopharmaceutical applications

  • With gamma sterilisable disposable flow tube
  • One transmitter accommodates two flow tube diameters
  • Wetted material compliant with ISO 10993 and USP Class VI
  • High accuracy (±1% of MV), wide measuring range, no recalibration

OPTIFLUX 4100

Electromagnetic flowmeter for standard applications with abrasive and aggressive liquids

  • Chemically resistant, for liquids (>5 μS/cm) with solid content (≤10%)
  • Up to +180°C / +356°F
  • Flange: DN2.5…1200 / ⅒…48", max. PN40 / ASME Cl 1500
  • 4…20 mA, pulse, frequency, status, HART®

OPTIFLUX 4300

Electromagnetic flowmeter for advanced process and custody transfer (CT) applications

  • High accuracy (±0.2%), certified for custody transfer
  • For low conductivity media (>1 μS/cm) and high solid contents (≤70%)
  • Flange: DN2.5…3000 / ⅒…120", max. PN40 / ASME Cl 1500
  • 3 x 4…20 mA, HART®,Modbus, FF, Profibus-PA/DP, PROFINET

POWERFLUX 4300

Electromagnetic flowmeter for nuclear applications

  • Designed and tested for industrial nuclear environments
  • With resistant ETFE or PFA liner materials
  • Flange: DN25…1000 / 1…40"
  • 3 x 4…20 mA, HART®, Modbus, FF, Profibus-PA/DP, PROFINET

POWERFLUX 5030

Electromagnetic flowmeter for nuclear applications

  • Designed and tested for industrial nuclear environments
  • With high-tech ceramic tube (DN2.5…100 / 110…4") for very aggressive and abrasive fluids
  • Free of programmable electronic components
  • 4…20 mA

OPTIFLUX 5100

Electromagnetic flowmeter for demanding applications with aggressive and abrasive media

  • With chemically resistant ceramic tube for liquids with solid content (≤10%)
  • Up to +180°C / +356°F
  • Flange: DN2.5…300 / ⅒…12", max. PN40 / ASME Cl 300; Wafer: max. DN100 / 4"
  • 4…20 mA, pulse, frequency, status, HART®

OPTIFLUX 5300

Electromagnetic flowmeter for advanced process and master meter applications

  • Highest accuracy (±0.15%), with ceramic tube for aggressive and abrasive liquids (≤70% solid content) up to +180°C / +356°F
  • CT: OIML R117, MI-005 etc.
  • Flange: DN2.5…300 / 1/10…12", max. PN40 / ASME Cl 300; Wafer: DN100 / 4"
  • 3 x 4…20 mA, HART®, Modbus, FF, Profibus-PA/DP, PROFINET

POWERFLUX 5300

Electromagnetic flowmeter for nuclear applications

  • Designed and tested for industrial nuclear environments
  • With high-tech ceramic tube for very aggressive and abrasive fluids
  • Space-saving wafer design: DN2.5…100 / 1⁄10…4"
  • 3 x 4…20 mA, HART®, Modbus, FF, Profibus-PA/DP, PROFINET

BATCHFLUX 5500

Electromagnetic flowmeter for demanding volumetric filling applications for a wide range of container sizes

  • High accuracy measurement in process batching as well as cold or hot filling of conductive liquids, e.g. milk, fruit drinks with solid content, detergents etc.
  • With ceramic measuring tube and sintered electrodes for applications up to 16 bar / 232 psi
  • Flow tube conforms to EC1935/2004, FDA, GB 4806; 3A certified up to DN25 / 1"
  • Frequency output integrated

BATCHFLUX 3100

New

Electromagnetic flowmeter for the volumetric filling of common container sizes

  • The most compact filling mag meter in the market for filling of conductive liquids, e.g. water, carbonized soft drinks etc.
  • Lightweight, economical design with ceramic flow tube for applications up to 8 bar / 116 psi
  • The DN15 / ½″ ceramic tube conforms to EC1935/2004, FDA, GB 4806
  • Frequency output integrated