Showing 1–12 of 112 results

WATERFLUX 3000

Electromagnetic flow sensor for combination with IFC 050, IFC 070, IFC 100 and IFC 300 flow converters

  • Unique rectangular sensor design
  • Connection sizes: DN25…600 / 1…24"
  • Liner: Rilsan®

TIDALFLUX 2000

Electromagnetic flow sensor for combination with IFC 300 signal converter

  • Full bore design with non-wetted electrodes
  • Connection sizes: DN200…1600 / 8…64"
  • Liner: PUR

POWERFLUX 5000

Electromagnetic flow sensor for combination with AFC 030 and IFC 300 signal converters

  • Full bore design: pipe cross-section without restrictions
  • Connection sizes: DN2.5…100 / ⅒…4"
  • Tube material: Ceramic

POWERFLUX 4000

Electromagnetic flow sensor for combination with AFC 030 and IFC 300 signal converters

  • Full bore design: pipe cross-section without restrictions
  • Connection sizes: DN25…1000 / 1…40"
  • Liner: PFA or ETFE

OPTISONIC 8000

Ultrasonic flow sensor for combination with GFC 300 signal converter

  • Full bore design: pipe cross-section without restrictions
  • Connection sizes: DN100…1000 / 4…40"
  • Tube material: Carbon steel or alloy steel

OPTISONIC 7000 Biogas

Ultrasonic flow sensor for combination with GFC 300 signal converter

  • Full bore design without restrictions
  • Connection sizes: DN50…200 / 2…8"
  • Tube material: Stainless steel

OPTISONIC 7000

Ultrasonic flow sensor for combination with GFC 300 signal converter

  • Full bore design: pipe cross section without restrictions
  • Connection sizes: DN50…1000 / 2…40"
  • Tube material: Carbon steel or stainless steel

OPTISONIC 6000

Ultrasonic flow sensor for combination with UFC 300 signal converter

  • With robust stainless steel or aluminium rail
  • For pipe sizes: DN15…4000 / ½…160"
  • Optional small or medium sized versions for extended temperatures

OPTISONIC 3000

Ultrasonic flow sensor for combination with UFC 400 signal converter

  • Full bore design: pipe cross-section without restrictions
  • Connection sizes: DN25…3000 / 1…120"
  • Tube material: Carbon steel, stainless steel

OPTIMASS 7000

Coriolis mass flow sensor for combination with MFC 010 and MFC 400 signal converters

  • Single straight tube design
  • Connection sizes: DN10…100 / ½…4"
  • Tube material: Titanium, stainless steel, Hastelloy® or tantalum

OPTIMASS 6000

Coriolis mass flow sensor for combination with MFC 400 signal converter

  • Twin bent tube design
  • Connection sizes: DN10…300 / ½…12"
  • Tube material: Stainless steel, Hastelloy® or Duplex stainless steel

OPTIMASS 3000

Coriolis mass flow sensor for combination with MFC 010 and MFC 400 signal converters

  • Single Z-tube design
  • Connection sizes: DN15 / ½"
  • Tube material: Stainless steel or Hastelloy®